Comparison of Open Abdominal and Laparoscopic Bilateral Uterosacral Ligament Replacement: A One-Year Follow-Up Study.

Background: Pelvic organ prolapse significantly affects women's health, often requiring surgery. Unilateral sacrocolpopexy (SCP) is the gold standard for apical prolapse repair. However, varied SCP techniques can lead to inconsistencies in clinical outcomes, with differences in synthetic materials, mesh dimensions, placement, and apical tensioning. This variability may impact the comparability of clinical outcomes. Bilateral apical fixation has gained attention for its potential to provide effective apical support and restore anatomical integrity. Objective: To date there are not many studies on bilateral apical cervicosacropexy between the vaginal apex and the sacrum at the level of S1/promontory with one-year follow-up. Methods: This study presents a one-year follow-up comparing the clinical outcomes of open abdominal (CESA) and laparoscopic cervicosacropexy (laCESA) for bilateral apical suspension in women with pelvic floor disorders. A total of 145 women underwent either CESA (n = 75) or laCESA (n = 70) using a surgical technique with a designed polyvinylidene-fluoride (PVDF) mesh of defined shape replacing both uterosacral ligaments. Outcomes were efficacy, safety, and success rates of both surgical approaches in restoring apical vaginal support and pelvic floor functioning. Results: Both techniques demonstrated high efficacy of apical prolapse repair and a high level of safety. While comparable rates of urinary continence restoration were achieved, laCESA showed significant advantages in terms of operative time, hospital stay, and recovery time. Conclusions: These findings demonstrate the reproducibility of a surgical technique including clinical outcomes in the treatment of pelvic floor dysfunction. The standardization of mesh design and surgical methodology enhances reproducibility and may mitigate some of the variability associated with clinical outcomes in apical mesh fixation techniques.

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-03-11
DOI
https://doi.org/10.48620/87259
Primary Topic
Consumer behavior in food and health
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Open Abdominal and Laparoscopic Bilateral Uterosacral Ligament Replacement: A One-Year Follow-Up Study.

Open Access CRIS of the University of Bern
Consumer behavior in food and health
article

Comparison of Open Abdominal and Laparoscopic Bilateral Uterosacral Ligament Replacement: A One-Year Follow-Up Study.

article en

Abstract

Background: Pelvic organ prolapse significantly affects women's health, often requiring surgery. Unilateral sacrocolpopexy (SCP) is the gold standard for apical prolapse repair. However, varied SCP techniques can lead to inconsistencies in clinical outcomes, with differences in synthetic materials, mesh dimensions, placement, and apical tensioning. This variability may impact the comparability of clinical outcomes. Bilateral apical fixation has gained attention for its potential to provide effective apical support and restore anatomical integrity. Objective: To date there are not many studies on bilateral apical cervicosacropexy between the vaginal apex and the sacrum at the level of S1/promontory with one-year follow-up. Methods: This study presents a one-year follow-up comparing the clinical outcomes of open abdominal (CESA) and laparoscopic cervicosacropexy (laCESA) for bilateral apical suspension in women with pelvic floor disorders. A total of 145 women underwent either CESA (n = 75) or laCESA (n = 70) using a surgical technique with a designed polyvinylidene-fluoride (PVDF) mesh of defined shape replacing both uterosacral ligaments. Outcomes were efficacy, safety, and success rates of both surgical approaches in restoring apical vaginal support and pelvic floor functioning. Results: Both techniques demonstrated high efficacy of apical prolapse repair and a high level of safety. While comparable rates of urinary continence restoration were achieved, laCESA showed significant advantages in terms of operative time, hospital stay, and recovery time. Conclusions: These findings demonstrate the reproducibility of a surgical technique including clinical outcomes in the treatment of pelvic floor dysfunction. The standardization of mesh design and surgical methodology enhances reproducibility and may mitigate some of the variability associated with clinical outcomes in apical mesh fixation techniques.

Open Access CRIS of the University of Bern
Good health and well-being
Openalex Percentile: Top 44%
Consumer behavior in food and health
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparison of Open Abdominal and Laparoscopic Bilateral Uterosacral Ligament Replacement: A One-Year Follow-Up Study. · Open Access CRIS of the University of Bern (2025) | TGRS Research Map | TGRS