Comparing analog and 3D measurements of vertical dimension in edentulous subjects.

Objective This study aimed to explore the feasibility and reliability of measuring the vertical dimension of occlusion/rest (OVD/RVD) on 3D facial scans of edentulous patients. Methods Nineteen edentulous participants rehabilitated with complete removable dental prostheses (CDs) participated in this study. Analog measurements (control) were obtained directly on the face for each participant with the jaws positioned at the rest position (without CDs, RVD) and at central occlusion (OVD), between the facial landmarks: Glabella (G) and Soft Pogonion (SP), Pronasale (PN) and SP, and Subnasale (SN) and SP. Participants' faces were scanned twice, using a face-scanner (Class 1 LASER, Obiscanner). Scans were imported into a mesh-processing software, and the OVD/RVD were measured digitally. Two investigators performed all the measurements and were blinded. Data analysis included intra-class correlation coefficient (ICC) and pairwise comparison tests (p<0.05). Results Digital measurements were higher than analog measurements, and the mean paired difference ranged from -4.86±3.2 to 0.42±2.7 mm. All the differences were statistically significant, expect for SN-SP (p=0.110). Magnitude of the differences for the RVD were large for G-SP and SN-SP (ES>0.80) and moderate for PN-SP (ES>0.50). There was a large effect for G-SP when measuring OVD (ES>0.50), and small effect for PN-SP and SN-SP (ES≤0.20). Conclusion Considering the limitations associated with the specific type of facial scanner used in this study, it can be concluded that registering the resting vertical dimension in edentulous patients through digital methods may not be recommended. This is due to the potential errors that may arise during the data acquisition process, which could compromise the accuracy and reliability of the measurements. Clinical Significance Digital methods for registering the vertical dimension of rest (RVD) in edentulous patients can introduce errors, resulting in occlusal errors and discomfort. Clinicians must, for the moment, still use conventional analog methods to ensure accurate RVD measurement for a successful denture therapy.

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-02-04
DOI
https://doi.org/10.48620/85147
Primary Topic
Orthodontics and Dentofacial Orthopedics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparing analog and 3D measurements of vertical dimension in edentulous subjects.

Open Access CRIS of the University of Bern
Orthodontics and Dentofacial Orthopedics
article

Comparing analog and 3D measurements of vertical dimension in edentulous subjects.

article en

Abstract

Objective This study aimed to explore the feasibility and reliability of measuring the vertical dimension of occlusion/rest (OVD/RVD) on 3D facial scans of edentulous patients. Methods Nineteen edentulous participants rehabilitated with complete removable dental prostheses (CDs) participated in this study. Analog measurements (control) were obtained directly on the face for each participant with the jaws positioned at the rest position (without CDs, RVD) and at central occlusion (OVD), between the facial landmarks: Glabella (G) and Soft Pogonion (SP), Pronasale (PN) and SP, and Subnasale (SN) and SP. Participants' faces were scanned twice, using a face-scanner (Class 1 LASER, Obiscanner). Scans were imported into a mesh-processing software, and the OVD/RVD were measured digitally. Two investigators performed all the measurements and were blinded. Data analysis included intra-class correlation coefficient (ICC) and pairwise comparison tests (p<0.05). Results Digital measurements were higher than analog measurements, and the mean paired difference ranged from -4.86±3.2 to 0.42±2.7 mm. All the differences were statistically significant, expect for SN-SP (p=0.110). Magnitude of the differences for the RVD were large for G-SP and SN-SP (ES>0.80) and moderate for PN-SP (ES>0.50). There was a large effect for G-SP when measuring OVD (ES>0.50), and small effect for PN-SP and SN-SP (ES≤0.20). Conclusion Considering the limitations associated with the specific type of facial scanner used in this study, it can be concluded that registering the resting vertical dimension in edentulous patients through digital methods may not be recommended. This is due to the potential errors that may arise during the data acquisition process, which could compromise the accuracy and reliability of the measurements. Clinical Significance Digital methods for registering the vertical dimension of rest (RVD) in edentulous patients can introduce errors, resulting in occlusal errors and discomfort. Clinicians must, for the moment, still use conventional analog methods to ensure accurate RVD measurement for a successful denture therapy.

Open Access CRIS of the University of Bern
Openalex Percentile: Top 44%
Orthodontics and Dentofacial Orthopedics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.