One-Step Focusing of Ampholytes With Electrophoretic Mobilization: Concepts Assessed by Computer Simulation.

The dynamics of three one-step focusing protocols described in the literature for IEF-MS analyses of proteins are assessed by computer simulation. Focusing of 101 carrier ampholytes (pI range 3.0-11.0) and 9 analytes (pI range 3.9-10.4) with concurrent electrophoretic mobilization in an electroosmosis-free environment is studied via use of the following: (1) an acid as anolyte and catholyte, (2) a plug of a base between the sample and the acid as catholyte, and (3) a base incorporated into the acid-based catholyte. The data reveal that the first approach is of limited applicability and separation efficiency as it provides separated transient foci of acidic ampholytes only. The second system largely extends the applicability range, separation, and sensitivity and can be applied to ampholytes with pIs as high as 10. The same is true with the base incorporated into the catholyte. Dynamic simulation provides for the first time insight into the complexity of these one-step focusing systems with buffer components that are compatible with MS detection. Simulation is an attractive and simple tool for characterization of the involved electrophoretic processes and for assay optimization.

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2024-12-23
DOI
https://doi.org/10.48620/78694
Primary Topic
Microfluidic and Capillary Electrophoresis Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

One-Step Focusing of Ampholytes With Electrophoretic Mobilization: Concepts Assessed by Computer Simulation.

Open Access CRIS of the University of Bern
Microfluidic and Capillary Electrophoresis Applications
article

One-Step Focusing of Ampholytes With Electrophoretic Mobilization: Concepts Assessed by Computer Simulation.

article en

Abstract

The dynamics of three one-step focusing protocols described in the literature for IEF-MS analyses of proteins are assessed by computer simulation. Focusing of 101 carrier ampholytes (pI range 3.0-11.0) and 9 analytes (pI range 3.9-10.4) with concurrent electrophoretic mobilization in an electroosmosis-free environment is studied via use of the following: (1) an acid as anolyte and catholyte, (2) a plug of a base between the sample and the acid as catholyte, and (3) a base incorporated into the acid-based catholyte. The data reveal that the first approach is of limited applicability and separation efficiency as it provides separated transient foci of acidic ampholytes only. The second system largely extends the applicability range, separation, and sensitivity and can be applied to ampholytes with pIs as high as 10. The same is true with the base incorporated into the catholyte. Dynamic simulation provides for the first time insight into the complexity of these one-step focusing systems with buffer components that are compatible with MS detection. Simulation is an attractive and simple tool for characterization of the involved electrophoretic processes and for assay optimization.

Open Access CRIS of the University of Bern
Sustainable cities and communities
Openalex Percentile: Top 66%
Microfluidic and Capillary Electrophoresis Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.