Five-Year Outcomes with Self-expanding versus Balloon-expandable TAVI in Patients with Left Ventricular Systolic Dysfunction.

Background The importance of transcatheter heart valve (THV) design on clinical outcome in patients with aortic stenosis (AS) and left ventricular (LV) systolic dysfunction remains unknown. Objectives We aimed to compare 5-year outcomes of patients with severe AS and reduced LV ejection fraction (LVEF), undergoing transcatheter aortic valve implantation (TAVI) with balloon-expandable vs. self-expanding THVs. Methods In a retrospective analysis from the Bern TAVI registry, patients with LVEF <50% who underwent TAVI with either balloon-expandable or self-expanding THVs were included. A 1:1 propensity-score matching was performed to account for baseline differences between groups. Results A total of 759 patients were included between August 2007 and December 2022, and propensity-score matching resulted in 134 pairs. Technical success was achieved in over 85% of patients, and was similar in both groups. Self-expanding THVs were associated with a lower mean transvalvular gradient (7.1 ± 3.7 mmHg vs. 9.9 ± 4.3 mmHg; P <0.001) and a higher incidence of ≥mild-to-moderate paravalvular regurgitation (36.3% vs. 11.3%; P <0.001) compared to balloon-expandable THVs. At 5 years, patients treated with a self-expanding THV had higher all-cause mortality than those with a balloon-expandable THV (67.8% vs. 55.8%, HRadjusted: 1.44; 95% CI: 1.02-2.03; P = 0.037). There were no significant differences in other clinical outcomes up to 5 years between groups. Conclusions In the setting of LV systolic dysfunction, patients treated with a self-expanding THV had higher risk of 5-year mortality compared to patients treated with a balloon-expandable THV. Clinical Trial Registration https://www. Clinicaltrials gov. NCT01368250.

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2024-12-10
DOI
https://doi.org/10.48620/77326
Primary Topic
Research Data Management Practices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Five-Year Outcomes with Self-expanding versus Balloon-expandable TAVI in Patients with Left Ventricular Systolic Dysfunction.

Open Access CRIS of the University of Bern
Research Data Management Practices
article

Five-Year Outcomes with Self-expanding versus Balloon-expandable TAVI in Patients with Left Ventricular Systolic Dysfunction.

article en

Abstract

Background The importance of transcatheter heart valve (THV) design on clinical outcome in patients with aortic stenosis (AS) and left ventricular (LV) systolic dysfunction remains unknown. Objectives We aimed to compare 5-year outcomes of patients with severe AS and reduced LV ejection fraction (LVEF), undergoing transcatheter aortic valve implantation (TAVI) with balloon-expandable vs. self-expanding THVs. Methods In a retrospective analysis from the Bern TAVI registry, patients with LVEF <50% who underwent TAVI with either balloon-expandable or self-expanding THVs were included. A 1:1 propensity-score matching was performed to account for baseline differences between groups. Results A total of 759 patients were included between August 2007 and December 2022, and propensity-score matching resulted in 134 pairs. Technical success was achieved in over 85% of patients, and was similar in both groups. Self-expanding THVs were associated with a lower mean transvalvular gradient (7.1 ± 3.7 mmHg vs. 9.9 ± 4.3 mmHg; P <0.001) and a higher incidence of ≥mild-to-moderate paravalvular regurgitation (36.3% vs. 11.3%; P <0.001) compared to balloon-expandable THVs. At 5 years, patients treated with a self-expanding THV had higher all-cause mortality than those with a balloon-expandable THV (67.8% vs. 55.8%, HRadjusted: 1.44; 95% CI: 1.02-2.03; P = 0.037). There were no significant differences in other clinical outcomes up to 5 years between groups. Conclusions In the setting of LV systolic dysfunction, patients treated with a self-expanding THV had higher risk of 5-year mortality compared to patients treated with a balloon-expandable THV. Clinical Trial Registration https://www. Clinicaltrials gov. NCT01368250.

Open Access CRIS of the University of Bern
United Heart and Vascular Clinic (US), IST Research (US)
Good health and well-being
Openalex Percentile: Top 39%
Research Data Management Practices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Five-Year Outcomes with Self-expanding versus Balloon-expandable TAVI in Patients with Left Ventricular Systolic Dysfunction. · Open Access CRIS of the University of Bern (2024) | TGRS Research Map | TGRS