Multicenter Evaluation of the QIAstat-Dx and the BioFire Multiplex Panel Tests for the Detection of Respiratory Pathogens.

Syndromic multiplex panel testing enables simultaneous detection of multiple respiratory pathogens, but limited data is available on the comparative diagnostic performance of different testing systems. In this multicenter prospective study, we aimed to compare the QIAstat-Dx Respiratory Panel 2.0 (QIAstat-Dx-RP2.0) with the widely used BioFire-RP2.1, using 269 respiratory clinical specimens. Concordant test results were obtained in 232 (86.3%) cases. Discordant test results included 33 BioFire-RP2.1(+)/QIAstat-Dx-RP2.0(-) and 4 BioFire-RP2.1(-)/QIAstat-Dx-RP2.0(+) results. Discordant samples showed significantly lower pathogen loads than concordant ones (p < 0.01). Overall, the QIAstat-Dx-RP2.0 showed an analytical sensitivity of 50%-100% depending on the respiratory target, with an analytical specificity ≥ 99.0%. Most significant differences were found for the detection of adenovirus, human coronaviruses, respiratory syncytial virus, human rhinovirus/enterovirus and SARS-CoV-2 (kappa-score: 0.67-0.91). Co-detections of respiratory pathogens were identified in 47 cases by BioFire-RP2.1 and 29 by QIAstat-Dx-RP2.0. Agreement rates between the two multiplex panel tests decreased from 91.8% for single pathogen detections to 65.0% and 42.9% for co-detecting two and three pathogens, respectively. Pathogen loads were significantly lower in co-detections compared to single pathogen detections (p < 0.01), potentially explaining the lower detection rates with the QIAstat-Dx-RP2.0 in cases of multiple pathogens. In conclusion, our prospective multicenter evaluation showed good diagnostic performance of the QIAstat-Dx-RP2.0 assay, but lower detection rates for some respiratory targets compared to BioFire-RP2.1. As QIAstat-Dx-RP2.0 offers advantages in handling, noise emission, cost effectiveness, and provides semi-quantitative results compared to BioFire-RP2.1 an updated version with enhanced analytical sensitivity would be a viable alternative syndromic testing system for detecting respiratory pathogens.

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2024-12-01
DOI
https://doi.org/10.48620/78823
Primary Topic
Respiratory viral infections research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multicenter Evaluation of the QIAstat-Dx and the BioFire Multiplex Panel Tests for the Detection of Respiratory Pathogens.

Open Access CRIS of the University of Bern
Respiratory viral infections research
article

Multicenter Evaluation of the QIAstat-Dx and the BioFire Multiplex Panel Tests for the Detection of Respiratory Pathogens.

article en

Abstract

Syndromic multiplex panel testing enables simultaneous detection of multiple respiratory pathogens, but limited data is available on the comparative diagnostic performance of different testing systems. In this multicenter prospective study, we aimed to compare the QIAstat-Dx Respiratory Panel 2.0 (QIAstat-Dx-RP2.0) with the widely used BioFire-RP2.1, using 269 respiratory clinical specimens. Concordant test results were obtained in 232 (86.3%) cases. Discordant test results included 33 BioFire-RP2.1(+)/QIAstat-Dx-RP2.0(-) and 4 BioFire-RP2.1(-)/QIAstat-Dx-RP2.0(+) results. Discordant samples showed significantly lower pathogen loads than concordant ones (p < 0.01). Overall, the QIAstat-Dx-RP2.0 showed an analytical sensitivity of 50%-100% depending on the respiratory target, with an analytical specificity ≥ 99.0%. Most significant differences were found for the detection of adenovirus, human coronaviruses, respiratory syncytial virus, human rhinovirus/enterovirus and SARS-CoV-2 (kappa-score: 0.67-0.91). Co-detections of respiratory pathogens were identified in 47 cases by BioFire-RP2.1 and 29 by QIAstat-Dx-RP2.0. Agreement rates between the two multiplex panel tests decreased from 91.8% for single pathogen detections to 65.0% and 42.9% for co-detecting two and three pathogens, respectively. Pathogen loads were significantly lower in co-detections compared to single pathogen detections (p < 0.01), potentially explaining the lower detection rates with the QIAstat-Dx-RP2.0 in cases of multiple pathogens. In conclusion, our prospective multicenter evaluation showed good diagnostic performance of the QIAstat-Dx-RP2.0 assay, but lower detection rates for some respiratory targets compared to BioFire-RP2.1. As QIAstat-Dx-RP2.0 offers advantages in handling, noise emission, cost effectiveness, and provides semi-quantitative results compared to BioFire-RP2.1 an updated version with enhanced analytical sensitivity would be a viable alternative syndromic testing system for detecting respiratory pathogens.

Open Access CRIS of the University of Bern
Infectious Disease Research Institute (US), EP Analytics (United States) (US), Infectious Diseases Institute (UG)
Openalex Percentile: Top 50%
Respiratory viral infections research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.