Pulmonary nodule visualization and evaluation of AI-based detection at various ultra-low-dose levels using photon-counting detector CT

BACKGROUND Radiation dose should be as low as reasonably achievable. With the invention of photon-counting detector computed tomography (PCD-CT), the radiation dose may be considerably reduced. PURPOSE To evaluate the potential of PCD-CT for dose reduction in pulmonary nodule visualization for human readers as well as for computer-aided detection (CAD) studies. MATERIAL AND METHODS A chest phantom containing pulmonary nodules of different sizes/densities (range 3-12 mm and -800-100 HU) was scanned on a PCD-CT with standard low-dose protocol as well as with half, quarter, and 1/40 dose (CTDI$_{vol}$ 0.4-0.03 mGy). Dose-matched scans were performed on a third-generation energy-integrating detector CT (EID-CT). Evaluation of nodule visualization and detectability was performed by two blinded radiologists. Subjective image quality was rated on a 5-point Likert scale. Artificial intelligence (AI)-based nodule detection was performed using commercially available software. RESULTS Highest image noise was found at the lowest dose setting of 1/40 radiation dose (eff. dose = 0.01mSv) with 166.1 ± 18.5 HU for PCD-CT and 351.8 ± 53.0 HU for EID-CT. Overall sensitivity was 100% versus 93% at standard low-dose protocol (eff. dose = 0.2 mSv) for PCD-CT and EID-CT, respectively. At the half radiation dose, sensitivity remained 100% for human reader and CAD studies in PCD-CT. At the quarter radiation dose, PCD-CT achieved the same results as EID-CT at the standard radiation dose setting (93%, P = 1.00) in human reading studies. The AI-CAD system delivered a sensitivity of 93% at the lowest radiation dose level in PCD-CT. CONCLUSION At half dose, PCD CT showed pulmonary nodules similar to full-dose PCD, and at quarter dose, PCD CT performed comparably to standard low-dose EID CT. The CAD algorithm is effective even at ultra-low doses.

Publication Details

Journal
Zurich Open Repository and Archive (University of Zurich)
Published
2024-10-01
DOI
https://doi.org/10.5167/uzh-262798
Primary Topic
Species Distribution and Climate Change
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pulmonary nodule visualization and evaluation of AI-based detection at various ultra-low-dose levels using photon-counting detector CT

Zurich Open Repository and Archive (University of Zurich)
Species Distribution and Climate Change
article

Pulmonary nodule visualization and evaluation of AI-based detection at various ultra-low-dose levels using photon-counting detector CT

article en

Abstract

BACKGROUND Radiation dose should be as low as reasonably achievable. With the invention of photon-counting detector computed tomography (PCD-CT), the radiation dose may be considerably reduced. PURPOSE To evaluate the potential of PCD-CT for dose reduction in pulmonary nodule visualization for human readers as well as for computer-aided detection (CAD) studies. MATERIAL AND METHODS A chest phantom containing pulmonary nodules of different sizes/densities (range 3-12 mm and -800-100 HU) was scanned on a PCD-CT with standard low-dose protocol as well as with half, quarter, and 1/40 dose (CTDI$_{vol}$ 0.4-0.03 mGy). Dose-matched scans were performed on a third-generation energy-integrating detector CT (EID-CT). Evaluation of nodule visualization and detectability was performed by two blinded radiologists. Subjective image quality was rated on a 5-point Likert scale. Artificial intelligence (AI)-based nodule detection was performed using commercially available software. RESULTS Highest image noise was found at the lowest dose setting of 1/40 radiation dose (eff. dose = 0.01mSv) with 166.1 ± 18.5 HU for PCD-CT and 351.8 ± 53.0 HU for EID-CT. Overall sensitivity was 100% versus 93% at standard low-dose protocol (eff. dose = 0.2 mSv) for PCD-CT and EID-CT, respectively. At the half radiation dose, sensitivity remained 100% for human reader and CAD studies in PCD-CT. At the quarter radiation dose, PCD-CT achieved the same results as EID-CT at the standard radiation dose setting (93%, P = 1.00) in human reading studies. The AI-CAD system delivered a sensitivity of 93% at the lowest radiation dose level in PCD-CT. CONCLUSION At half dose, PCD CT showed pulmonary nodules similar to full-dose PCD, and at quarter dose, PCD CT performed comparably to standard low-dose EID CT. The CAD algorithm is effective even at ultra-low doses.

Zurich Open Repository and Archive (University of Zurich)
Quality Education
Openalex Percentile: Top 56%
Species Distribution and Climate Change
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Pulmonary nodule visualization and evaluation of AI-based detection at various ultra-low-dose levels using photon-counting detector CT · Zurich Open Repository and Archive (University of Zurich) (2024) | TGRS Research Map | TGRS