Distortion Assessment of Different Materials in Full-Arch Dentate Impressions in Relation to Operator Experience: A Comparative In Vivo Study.

Purpose To evaluate the distortion probability in impressions of completely dentate arches when different impression materials are used in relation to operator experience.Materials And Methods A total of 28 students (Group A) and 7 dentists (Group B) performed three maxillary impressions on 28 participants, each using vinyl siloxane ether (VSE), polyether (PE), and irreversible hydrocolloid (IHC). Gypsum master casts were fabricated and subsequently digitized. Intraoral scans were taken as a control. Differences between master casts and intraoral scans were visualized with heatmaps, and planar deviations were investigated. If planar deviations > 120 μm were found, the impression was rated as 'distorted.' An additional superimposition using the casts from VSE or PE was performed to confirm the presence of distortions. The relative number of surfaces with distortions in each impression was calculated. The procedure was repeated for a distortion threshold of 500 μm. The statistical analyses included repeated measures ANOVA (RMA) and post hoc tests (α < .05).Results When 120 μm was considered as the threshold for distortions, IHC impressions showed higher distortion probability than PE impressions in Group A (P = .003) and Group B (P < .0001). In Group B, PE showed a lower distortion probability than VSE (P = .02). There was no significant difference between the study groups (P = .42). Considering 500 μm as a threshold for distortions, there was no difference between impression materials (P = .17) or study groups (P = .53).Conclusions There were no statistically significant differences in relation to operator experience. Different impression materials had a significant impact on distortion probability. PE impressions showed the lowest distortion probability.

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2024-09-27
DOI
https://doi.org/10.48620/87599
Primary Topic
Wood and Agarwood Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Distortion Assessment of Different Materials in Full-Arch Dentate Impressions in Relation to Operator Experience: A Comparative In Vivo Study.

Open Access CRIS of the University of Bern
Wood and Agarwood Research
article

Distortion Assessment of Different Materials in Full-Arch Dentate Impressions in Relation to Operator Experience: A Comparative In Vivo Study.

article en

Abstract

Purpose To evaluate the distortion probability in impressions of completely dentate arches when different impression materials are used in relation to operator experience.Materials And Methods A total of 28 students (Group A) and 7 dentists (Group B) performed three maxillary impressions on 28 participants, each using vinyl siloxane ether (VSE), polyether (PE), and irreversible hydrocolloid (IHC). Gypsum master casts were fabricated and subsequently digitized. Intraoral scans were taken as a control. Differences between master casts and intraoral scans were visualized with heatmaps, and planar deviations were investigated. If planar deviations > 120 μm were found, the impression was rated as 'distorted.' An additional superimposition using the casts from VSE or PE was performed to confirm the presence of distortions. The relative number of surfaces with distortions in each impression was calculated. The procedure was repeated for a distortion threshold of 500 μm. The statistical analyses included repeated measures ANOVA (RMA) and post hoc tests (α < .05).Results When 120 μm was considered as the threshold for distortions, IHC impressions showed higher distortion probability than PE impressions in Group A (P = .003) and Group B (P < .0001). In Group B, PE showed a lower distortion probability than VSE (P = .02). There was no significant difference between the study groups (P = .42). Considering 500 μm as a threshold for distortions, there was no difference between impression materials (P = .17) or study groups (P = .53).Conclusions There were no statistically significant differences in relation to operator experience. Different impression materials had a significant impact on distortion probability. PE impressions showed the lowest distortion probability.

Open Access CRIS of the University of Bern
University of Dental Medicine (MM)
Openalex Percentile: Top 66%
Wood and Agarwood Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Distortion Assessment of Different Materials in Full-Arch Dentate Impressions in Relation to Operator Experience: A Comparative In Vivo Study. · Open Access CRIS of the University of Bern (2024) | TGRS Research Map | TGRS