Purpose The primary aim of this in vitro study was to investigate the primary implant stability obtained in immediate and late implant placement scenarios. Secondary aims evaluated the effect of two distinct implant macro-designs and examined the correlation between resonance frequency analysis (RFA) and final insertion torque. Methods Partially edentulous maxillary models including six single sites simulating extraction sockets and healed alveolar ridges were used. Virtual implant planning facilitated static computer-assisted implant placement of bone level implants with either a shallow-threaded and cylindrical (BL), or deep-threaded and tapered implant macro-design (BLX). The insertion torque was continuously measured during implant placement, and RFA was performed after final implant positioning. Results One-hundred and forty-four implants were equally distributed to two alveolar ridge morphologies and implant designs. Higher final insertion torque and RFA values were observed for implants placed in healed ridges compared to extraction sockets (40.8 ± 13.5 vs. 20.6 ± 8.4 Ncm, and RFA 70.7 ± 2.8 vs. 59.6 ± 6.5, both p < 0.001), and for BL implants compared to BLX implants (35.7 ± 13.0 vs. 25.7 ± 8.9 Ncm, and RFA 66.7 ± 4.4 vs. 63.6 ± 4.9, both p < 0.001). Insertion torque and mean RFA values positively correlated (r = 0.742; p < 0.001). Conclusion Primary implant stability is significantly affected by the alveolar ridge morphology and the implant macro-design, demonstrating higher values in healed sites and shallow-threaded, cylindrical implants. Therefore, a tailored selection of the implant design depending on the implant placement and loading protocol is recommended.

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-03-06
DOI
https://doi.org/10.48620/86620
Primary Topic
Remote Sensing and LiDAR Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Primary implant stability of two implant macro-designs in different alveolar ridge morphologies: an in vitro study.

Open Access CRIS of the University of Bern
Remote Sensing and LiDAR Applications
article

Primary implant stability of two implant macro-designs in different alveolar ridge morphologies: an in vitro study.

article en

Abstract

Purpose The primary aim of this in vitro study was to investigate the primary implant stability obtained in immediate and late implant placement scenarios. Secondary aims evaluated the effect of two distinct implant macro-designs and examined the correlation between resonance frequency analysis (RFA) and final insertion torque. Methods Partially edentulous maxillary models including six single sites simulating extraction sockets and healed alveolar ridges were used. Virtual implant planning facilitated static computer-assisted implant placement of bone level implants with either a shallow-threaded and cylindrical (BL), or deep-threaded and tapered implant macro-design (BLX). The insertion torque was continuously measured during implant placement, and RFA was performed after final implant positioning. Results One-hundred and forty-four implants were equally distributed to two alveolar ridge morphologies and implant designs. Higher final insertion torque and RFA values were observed for implants placed in healed ridges compared to extraction sockets (40.8 ± 13.5 vs. 20.6 ± 8.4 Ncm, and RFA 70.7 ± 2.8 vs. 59.6 ± 6.5, both p < 0.001), and for BL implants compared to BLX implants (35.7 ± 13.0 vs. 25.7 ± 8.9 Ncm, and RFA 66.7 ± 4.4 vs. 63.6 ± 4.9, both p < 0.001). Insertion torque and mean RFA values positively correlated (r = 0.742; p < 0.001). Conclusion Primary implant stability is significantly affected by the alveolar ridge morphology and the implant macro-design, demonstrating higher values in healed sites and shallow-threaded, cylindrical implants. Therefore, a tailored selection of the implant design depending on the implant placement and loading protocol is recommended.

Open Access CRIS of the University of Bern
Stomatology Hospital (CN)
Openalex Percentile: Top 56%
Remote Sensing and LiDAR Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.