Advancing HR-pQCT-based homogenised FE models with smooth structured hexahedral meshes.

Nonlinear homogenised finite element (hFE) models can accurately predict stiffness and strength of ultra-distal sections of the radius and tibia using in vivo HR-pQCT images. Recent findings showed good stiffness prediction at these distal sections but a limited ability to reproduce experimental strain localisation. The coarseness of voxel-based meshes reduces the computational effort at the cost of heavily simplifying the underlying geometry of the cortex, the gradient of material properties, and the resulting strain distribution. To overcome these limitations, we present a comprehensive approach to generating fully automated, smooth, and structured hexahedral meshes for HR-pQCT scans at the distal radius and tibia. This study used three datasets to validate the proposed hFE pipeline and its short-term repeatability: ex vivo 2nd generation HR-pQCT images of 21 human radii and 25 human tibiae, and 208 in vivo images from same-day repeated scans on 39 individuals. Results show high accuracy in predicting stiffness (tibia: R2=0.94, radius: R2=0.88) and yield force (tibia: R2=0.93, radius: R2=0.95). Mesh sensitivity analysis reveals stabilisation within a ± 3 % error margin. Dice similarity coefficients between mesh and scanned image were >0.99, and good element quality was achieved across the validation datasets (tibia: S-ICNavg=0.809, radius: S-ICNavg=0.764). Along with the improved volumetric representation of distal cortical and trabecular bone geometry and the good element quality, the new pipeline shows gains in computational performance: 11.70±1.49 min for triple-stack tibia images and 11.00±0.97 min for double-stack radius images, respectively. Generating structured meshes with consistent element-to-element correspondence facilitates seamless comparison between patient models or in longitudinal settings, providing an additional clinical information.

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-02-05
DOI
https://doi.org/10.48620/85192
Primary Topic
Wood and Agarwood Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Advancing HR-pQCT-based homogenised FE models with smooth structured hexahedral meshes.

Open Access CRIS of the University of Bern
Wood and Agarwood Research
article

Advancing HR-pQCT-based homogenised FE models with smooth structured hexahedral meshes.

article en

Abstract

Nonlinear homogenised finite element (hFE) models can accurately predict stiffness and strength of ultra-distal sections of the radius and tibia using in vivo HR-pQCT images. Recent findings showed good stiffness prediction at these distal sections but a limited ability to reproduce experimental strain localisation. The coarseness of voxel-based meshes reduces the computational effort at the cost of heavily simplifying the underlying geometry of the cortex, the gradient of material properties, and the resulting strain distribution. To overcome these limitations, we present a comprehensive approach to generating fully automated, smooth, and structured hexahedral meshes for HR-pQCT scans at the distal radius and tibia. This study used three datasets to validate the proposed hFE pipeline and its short-term repeatability: ex vivo 2nd generation HR-pQCT images of 21 human radii and 25 human tibiae, and 208 in vivo images from same-day repeated scans on 39 individuals. Results show high accuracy in predicting stiffness (tibia: R2=0.94, radius: R2=0.88) and yield force (tibia: R2=0.93, radius: R2=0.95). Mesh sensitivity analysis reveals stabilisation within a ± 3 % error margin. Dice similarity coefficients between mesh and scanned image were >0.99, and good element quality was achieved across the validation datasets (tibia: S-ICNavg=0.809, radius: S-ICNavg=0.764). Along with the improved volumetric representation of distal cortical and trabecular bone geometry and the good element quality, the new pipeline shows gains in computational performance: 11.70±1.49 min for triple-stack tibia images and 11.00±0.97 min for double-stack radius images, respectively. Generating structured meshes with consistent element-to-element correspondence facilitates seamless comparison between patient models or in longitudinal settings, providing an additional clinical information.

Open Access CRIS of the University of Bern
Biomechanics Institute of Valencia (ES)
Life below water
Openalex Percentile: Top 55%
Wood and Agarwood Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Advancing HR-pQCT-based homogenised FE models with smooth structured hexahedral meshes. · Open Access CRIS of the University of Bern (2025) | TGRS Research Map | TGRS