Performance and durability of additively and subtractively manufactured resin-based onlay restorations after thermomechanical aging.

Purpose To evaluate the effect of material type on dimensional stability, occlusal surface wear, fracture resistance, and failure behavior of resin-based onlay restorations. Material And Methods A mandibular right first molar typodont was prepared and digitized using an intraoral scanner to virtually design an onlay restoration with the minimum occlusal thickness of 1.5 mm. Resin-based onlay restorations (n = 15 per group) were fabricated either additively from 2 different resins indicated either for definitive or interim use or subtractively with a composite resin. After cementing onlays to corresponding dies, each of them was digitized before and after thermomechanical aging (B-STL and A-STL), and then subjected to load-to-failure test to evaluate fracture resistance. The B-STL and A-STL of each onlay were also compared to assess the dimensional stability and occlusal surface wear. One-way analysis of variance and Tukey honestly significant difference tests were used to evaluate dimensional stability, occlusal surface wear, and fracture resistance. The chi-square test was used to evaluate the Weibull modulus and characteristic strength among the groups (α = 0.05). Results Material type affected investigated outcomes (p < 0.001). The additively manufactured resin indicated for definitive use led to the highest external surface deviations and the additively manufactured resin indicated for interim use led to the highest mesiodistal width deviations (p ≤ 0.033). The onlays fabricated from the additively manufactured resin indicated for definitive use had the highest occlusal surface wear, while those in composite resin had the lowest (p ≤ 0.006). The composite resin onlays had the highest fracture resistance values and reliability (p ≤ 0.035). Conclusions Tested subtractively manufactured composite resin had the lowest occlusal surface wear with the highest fracture resistance and reliability. Additively manufactured resins had lower dimensional stability, while tested resin for additively manufactured definitive restorations had the highest occlusal surface wear.

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2024-12-18
DOI
https://doi.org/10.48620/84671
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance and durability of additively and subtractively manufactured resin-based onlay restorations after thermomechanical aging.

Open Access CRIS of the University of Bern
Dental materials and restorations
article

Performance and durability of additively and subtractively manufactured resin-based onlay restorations after thermomechanical aging.

article en

Abstract

Purpose To evaluate the effect of material type on dimensional stability, occlusal surface wear, fracture resistance, and failure behavior of resin-based onlay restorations. Material And Methods A mandibular right first molar typodont was prepared and digitized using an intraoral scanner to virtually design an onlay restoration with the minimum occlusal thickness of 1.5 mm. Resin-based onlay restorations (n = 15 per group) were fabricated either additively from 2 different resins indicated either for definitive or interim use or subtractively with a composite resin. After cementing onlays to corresponding dies, each of them was digitized before and after thermomechanical aging (B-STL and A-STL), and then subjected to load-to-failure test to evaluate fracture resistance. The B-STL and A-STL of each onlay were also compared to assess the dimensional stability and occlusal surface wear. One-way analysis of variance and Tukey honestly significant difference tests were used to evaluate dimensional stability, occlusal surface wear, and fracture resistance. The chi-square test was used to evaluate the Weibull modulus and characteristic strength among the groups (α = 0.05). Results Material type affected investigated outcomes (p < 0.001). The additively manufactured resin indicated for definitive use led to the highest external surface deviations and the additively manufactured resin indicated for interim use led to the highest mesiodistal width deviations (p ≤ 0.033). The onlays fabricated from the additively manufactured resin indicated for definitive use had the highest occlusal surface wear, while those in composite resin had the lowest (p ≤ 0.006). The composite resin onlays had the highest fracture resistance values and reliability (p ≤ 0.035). Conclusions Tested subtractively manufactured composite resin had the lowest occlusal surface wear with the highest fracture resistance and reliability. Additively manufactured resins had lower dimensional stability, while tested resin for additively manufactured definitive restorations had the highest occlusal surface wear.

Open Access CRIS of the University of Bern
University of Dental Medicine (MM)
Openalex Percentile: Top 59%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Performance and durability of additively and subtractively manufactured resin-based onlay restorations after thermomechanical aging. · Open Access CRIS of the University of Bern (2024) | TGRS Research Map | TGRS