Biomechanical evaluation of double-stranded knot configurations in high-strength sutures and tapes.

PURPOSE Recently, a new dynamic high-strength suture (DC) was introduced, also available in tape form (DT), featuring a salt-infused silicone core attracting water in a fluid environment to preserve tissue approximation. The aims of this study were to (1) assess the influence of securing throw number on knot security of two double-stranded knot configurations (Cow-hitch and Nice-knot) tied with either dynamic (DC and DT) or conventional (FW and ST) high-strength sutures and tapes, and (2) compare the ultimate force and knot slippage of the novel dynamic versus conventional sutures and tapes when used with their minimal number of needed securing throws. METHODS Seven specimens of each FW, ST, DC and DT were considered for tying with Cow-hitch or Nice-knots. The base of these Cow-hitch and Nice-knots was secured with surgeons` knots using 1-3 alternating throws. Tensile tests were conducted under physiologic conditions to evaluate knot slippage, ultimate force at rupture, and minimum number of throws ensuring 100% knot security. RESULTS: For both Cow-hitch and Nice-knots, 100% security was achieved with 2 securing throws for DC, DT, ST, and with 3 securing throws for FW. With these minimum numbers of securing throws, ultimate force was significantly higher for Nice-knots versus Cow-hitch tied with DT (p = 0.001) and slippage was significantly less with Nice-knots versus Cow-hitch tied with DC (p = 0.019). CONCLUSIONS The minimum number of securing throws required to achieve 100% security was 2 with DC, DT and ST for both Cow-hitch and Nice-knots configurations, in contrast to FW where 3 securing throws were needed. With these minimum numbers of securing throws, Nice-knots were associated with significantly higher ultimate forces when using DT and lower slippage with DC versus Cow-hitch knots.

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2024-10-26
DOI
https://doi.org/10.48350/198044
Primary Topic
Genomics and Phylogenetic Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanical evaluation of double-stranded knot configurations in high-strength sutures and tapes.

Open Access CRIS of the University of Bern
Genomics and Phylogenetic Studies
article

Biomechanical evaluation of double-stranded knot configurations in high-strength sutures and tapes.

article en

Abstract

PURPOSE Recently, a new dynamic high-strength suture (DC) was introduced, also available in tape form (DT), featuring a salt-infused silicone core attracting water in a fluid environment to preserve tissue approximation. The aims of this study were to (1) assess the influence of securing throw number on knot security of two double-stranded knot configurations (Cow-hitch and Nice-knot) tied with either dynamic (DC and DT) or conventional (FW and ST) high-strength sutures and tapes, and (2) compare the ultimate force and knot slippage of the novel dynamic versus conventional sutures and tapes when used with their minimal number of needed securing throws. METHODS Seven specimens of each FW, ST, DC and DT were considered for tying with Cow-hitch or Nice-knots. The base of these Cow-hitch and Nice-knots was secured with surgeons` knots using 1-3 alternating throws. Tensile tests were conducted under physiologic conditions to evaluate knot slippage, ultimate force at rupture, and minimum number of throws ensuring 100% knot security. RESULTS: For both Cow-hitch and Nice-knots, 100% security was achieved with 2 securing throws for DC, DT, ST, and with 3 securing throws for FW. With these minimum numbers of securing throws, ultimate force was significantly higher for Nice-knots versus Cow-hitch tied with DT (p = 0.001) and slippage was significantly less with Nice-knots versus Cow-hitch tied with DC (p = 0.019). CONCLUSIONS The minimum number of securing throws required to achieve 100% security was 2 with DC, DT and ST for both Cow-hitch and Nice-knots configurations, in contrast to FW where 3 securing throws were needed. With these minimum numbers of securing throws, Nice-knots were associated with significantly higher ultimate forces when using DT and lower slippage with DC versus Cow-hitch knots.

Open Access CRIS of the University of Bern
Hand and Upper Limb Clinic (CA)
Clean water and sanitation
Openalex Percentile: Top 59%
Genomics and Phylogenetic Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.