Effect of optimizing the selection of implantable collamer lens on postoperative vaults based on ultrasound biomicroscopy related data

AIM:To investigate the safety and efficacy of selecting implantable collamer lens(ICL)size for postoperative vaults using sulcus to sulcus(STS)and other data measured by ultrasound biomicroscopy(UBM), and to explore the relevant factors affecting vaults.METHODS: Prospective case observational study. A total of 95 patients(188 eyes)with ametropia who underwent ICL size optimization and 90 patients(174 eyes)without ICL size optimization, from January to December 2022 and underwent regular follow-up for 6 mo were selected. Patients were divided into an optimized group and a standard group based on whether ICL size optimization was performed. The patients were followed up at 1 d, 1 wk, 1, 3, and 6 mo, and uncorrected visual acuity(UCVA), best corrected visual acuity(BCVA), refraction state, intraocular pressure(IOP), corneal status, anterior chamber depth(ACD), angle opening, vaults and corneal endothelial cell count were collected.RESULTS: No significant difference in spherical equivalent, UCVA and BCVA was found between the two groups(all P >0.05). The safety index was 1.21±0.24 and 1.19±0.21 at 6 mo for the two groups, respectively, while the efficacy index were 1.18±0.22 and 1.07±0.26. The vaults at 6 mo for the two groups was 407.77±159.31 and 467.16±250.07 μm, respectively. In the optimization group, 92.0% of eyes achieved the desired vaults postoperatively, while 74.1% of eyes in the standard group reached the desired vaults. Both groups exhibited a slight downward trend in vaults over time, with no significant differences between the two groups(F=3.478, P=0.063). However, the standard group experienced 6 eyes of ICL replacement and 2 eyes of ICL removal due to acute angle-closure glaucoma induced by angle closure.CONCLUSION: Selecting the ICL size and determining the implantation orientation based on sulcus to sulcus(STS)and other data measured by UBM provides good safety, efficacy, and predictability for postoperative vaults.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-03-01
DOI
https://doi.org/10.3980/j.issn.1672-5123.2025.3.24
Primary Topic
Research Data Management Practices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of optimizing the selection of implantable collamer lens on postoperative vaults based on ultrasound biomicroscopy related data

SHILAP Revista de lepidopterología
Research Data Management Practices
article

Effect of optimizing the selection of implantable collamer lens on postoperative vaults based on ultrasound biomicroscopy related data

article en

Abstract

AIM:To investigate the safety and efficacy of selecting implantable collamer lens(ICL)size for postoperative vaults using sulcus to sulcus(STS)and other data measured by ultrasound biomicroscopy(UBM), and to explore the relevant factors affecting vaults.METHODS: Prospective case observational study. A total of 95 patients(188 eyes)with ametropia who underwent ICL size optimization and 90 patients(174 eyes)without ICL size optimization, from January to December 2022 and underwent regular follow-up for 6 mo were selected. Patients were divided into an optimized group and a standard group based on whether ICL size optimization was performed. The patients were followed up at 1 d, 1 wk, 1, 3, and 6 mo, and uncorrected visual acuity(UCVA), best corrected visual acuity(BCVA), refraction state, intraocular pressure(IOP), corneal status, anterior chamber depth(ACD), angle opening, vaults and corneal endothelial cell count were collected.RESULTS: No significant difference in spherical equivalent, UCVA and BCVA was found between the two groups(all P >0.05). The safety index was 1.21±0.24 and 1.19±0.21 at 6 mo for the two groups, respectively, while the efficacy index were 1.18±0.22 and 1.07±0.26. The vaults at 6 mo for the two groups was 407.77±159.31 and 467.16±250.07 μm, respectively. In the optimization group, 92.0% of eyes achieved the desired vaults postoperatively, while 74.1% of eyes in the standard group reached the desired vaults. Both groups exhibited a slight downward trend in vaults over time, with no significant differences between the two groups(F=3.478, P=0.063). However, the standard group experienced 6 eyes of ICL replacement and 2 eyes of ICL removal due to acute angle-closure glaucoma induced by angle closure.CONCLUSION: Selecting the ICL size and determining the implantation orientation based on sulcus to sulcus(STS)and other data measured by UBM provides good safety, efficacy, and predictability for postoperative vaults.

SHILAP Revista de lepidopterología
Openalex Percentile: Top 41%
Research Data Management Practices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.