Modelling exposure to aerosols from showers: Implications for microbial risk assessment

Inhalation of aerosols produced during showering exposes people to chemical and microbial contaminants present in the water. To improve quantitative estimates of exposure and to inform the efficacy of potential interventions to reduce exposures, the number and size distributions of aerosols generated during showering events were monitored and a mass balance model of the generated aerosols was developed. The aerosol generation rates were calculated through calibrating the model with the measured aerosol data. Specifically, aerosol count concentrations and size distributions were measured with an aerodynamic particle sizer over the duration of mock showering events under various conditions, including different water temperatures and different showerhead types (conventional and rain showers). The empirical data were then used to fit a mass balance model to obtain aerosol generation rates and decay rates for each aerosol size class through least square fitting. An initial high peak concentration of aerosols was observed under hot water conditions relative to cold water conditions which resulted in a rapid increase in aerosol exposure during the first 1–2 min of showering. This suggests that people showering in hot water conditions will have a potentially increased exposure during the first 1–2 min. The model-fitted values suggest large inter-experiment variation in estimated aerosol generation and decay rates, even among triplicates of the same showering conditions. Current exposure assessment approaches assume constant aerosol concentrations during showers which might lead to miscalculated cumulative risk for microbial hazards because of their uneven distribution in building plumbing systems and biofilm detachment process during flushing. Thus, considering aerosol dynamics is beneficial during shower exposure assessments to inform risk management interventions. The data set and associated modeling results provided can support this, as they can be readily integrated into microbial risk assessments for waterborne pathogens such as Legionella spp., nontuberculous Mycobacteria (NTM) and Pseudomonas aeruginosa.

Publication Details

Journal
Repository for Publications and Research Data (ETH Zurich)
Published
2025-05-01
DOI
https://doi.org/10.3929/ethz-b-000728258
Primary Topic
Species Distribution and Climate Change
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modelling exposure to aerosols from showers: Implications for microbial risk assessment

Repository for Publications and Research Data (ETH Zurich)
Species Distribution and Climate Change
article

Modelling exposure to aerosols from showers: Implications for microbial risk assessment

article en

Abstract

Inhalation of aerosols produced during showering exposes people to chemical and microbial contaminants present in the water. To improve quantitative estimates of exposure and to inform the efficacy of potential interventions to reduce exposures, the number and size distributions of aerosols generated during showering events were monitored and a mass balance model of the generated aerosols was developed. The aerosol generation rates were calculated through calibrating the model with the measured aerosol data. Specifically, aerosol count concentrations and size distributions were measured with an aerodynamic particle sizer over the duration of mock showering events under various conditions, including different water temperatures and different showerhead types (conventional and rain showers). The empirical data were then used to fit a mass balance model to obtain aerosol generation rates and decay rates for each aerosol size class through least square fitting. An initial high peak concentration of aerosols was observed under hot water conditions relative to cold water conditions which resulted in a rapid increase in aerosol exposure during the first 1–2 min of showering. This suggests that people showering in hot water conditions will have a potentially increased exposure during the first 1–2 min. The model-fitted values suggest large inter-experiment variation in estimated aerosol generation and decay rates, even among triplicates of the same showering conditions. Current exposure assessment approaches assume constant aerosol concentrations during showers which might lead to miscalculated cumulative risk for microbial hazards because of their uneven distribution in building plumbing systems and biofilm detachment process during flushing. Thus, considering aerosol dynamics is beneficial during shower exposure assessments to inform risk management interventions. The data set and associated modeling results provided can support this, as they can be readily integrated into microbial risk assessments for waterborne pathogens such as Legionella spp., nontuberculous Mycobacteria (NTM) and Pseudomonas aeruginosa.

Repository for Publications and Research Data (ETH Zurich)
Clean water and sanitation
Openalex Percentile: Top 53%
Species Distribution and Climate Change
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Modelling exposure to aerosols from showers: Implications for microbial risk assessment · Repository for Publications and Research Data (ETH Zurich) (2025) | TGRS Research Map | TGRS