Diagnostic accuracy of chest X-ray computer-aided detection software for detection of prevalent and incident tuberculosis in household contacts.

BACKGROUND: World Health Organization (WHO) tuberculosis (TB) screening guidelines recommend computer-aided detection (CAD) software for chest radiograph (CXR) interpretation. However, studies evaluating their diagnostic and prognostic accuracy are limited. METHODS: We conducted a prospective cohort study of household contacts of rifampicin-resistant TB in South Africa. Participants underwent baseline CXR and sputum investigation (routine [single spontaneous] and enhanced [additionally 2-3 induced]) for prevalent TB and follow-up for incident TB. Three CXR-CAD software products (CAD4TBv7.0, qXRv3.0.0, and Lunit INSIGHT v3.1.4.111) were compared. We evaluated their performance to detect routine and enhanced prevalent and incident TB, comparing performance with blood tests (Xpert MTB host-response, erythrocyte sedimentation rate, C-reactive protein, QuantiFERON) in a subgroup. RESULTS: 483 participants were followed up for 4.6 years (median). There were 23 prevalent (7 routinely diagnosed) and 38 incident TB cases. The AUC ROCs (95% CIs) to identify prevalent TB for CAD4TBv7.0, qXRv3.0.0, and Lunit INSIGHT v3.1.4.111 were .87 (.77-.96), .88 (.79-.97), and .91 (.83-.99), respectively. More than 30% with scores above recommended CAD thresholds who were bacteriologically negative on routine baseline sputum were subsequently diagnosed by enhanced sputum investigation or during follow-up. The AUC performance of baseline CAD to identify incident cases ranged between .60 and .65. Diagnostic performance of CAD for prevalent TB was superior to blood testing. CONCLUSIONS: Our findings suggest that the potential of CAD-CXR screening for TB is not maximized as a high proportion of those above current thresholds, but with a negative routine confirmatory sputum, have true TB disease that may benefit intervention.

Publication Details

Journal
The Francis Crick Institute
Published
2025-03-15
DOI
https://doi.org/10.25418/crick.28623596
Primary Topic
Tuberculosis Research and Epidemiology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnostic accuracy of chest X-ray computer-aided detection software for detection of prevalent and incident tuberculosis in household contacts.

The Francis Crick Institute
Tuberculosis Research and Epidemiology
article

Diagnostic accuracy of chest X-ray computer-aided detection software for detection of prevalent and incident tuberculosis in household contacts.

article en

Abstract

BACKGROUND: World Health Organization (WHO) tuberculosis (TB) screening guidelines recommend computer-aided detection (CAD) software for chest radiograph (CXR) interpretation. However, studies evaluating their diagnostic and prognostic accuracy are limited. METHODS: We conducted a prospective cohort study of household contacts of rifampicin-resistant TB in South Africa. Participants underwent baseline CXR and sputum investigation (routine [single spontaneous] and enhanced [additionally 2-3 induced]) for prevalent TB and follow-up for incident TB. Three CXR-CAD software products (CAD4TBv7.0, qXRv3.0.0, and Lunit INSIGHT v3.1.4.111) were compared. We evaluated their performance to detect routine and enhanced prevalent and incident TB, comparing performance with blood tests (Xpert MTB host-response, erythrocyte sedimentation rate, C-reactive protein, QuantiFERON) in a subgroup. RESULTS: 483 participants were followed up for 4.6 years (median). There were 23 prevalent (7 routinely diagnosed) and 38 incident TB cases. The AUC ROCs (95% CIs) to identify prevalent TB for CAD4TBv7.0, qXRv3.0.0, and Lunit INSIGHT v3.1.4.111 were .87 (.77-.96), .88 (.79-.97), and .91 (.83-.99), respectively. More than 30% with scores above recommended CAD thresholds who were bacteriologically negative on routine baseline sputum were subsequently diagnosed by enhanced sputum investigation or during follow-up. The AUC performance of baseline CAD to identify incident cases ranged between .60 and .65. Diagnostic performance of CAD for prevalent TB was superior to blood testing. CONCLUSIONS: Our findings suggest that the potential of CAD-CXR screening for TB is not maximized as a high proportion of those above current thresholds, but with a negative routine confirmatory sputum, have true TB disease that may benefit intervention.

The Francis Crick Institute
Good health and well-being
Openalex Percentile: Top 47%
Tuberculosis Research and Epidemiology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Diagnostic accuracy of chest X-ray computer-aided detection software for detection of prevalent and incident tuberculosis in household contacts. · The Francis Crick Institute (2025) | TGRS Research Map | TGRS