Comparison of retention in polyvinyl siloxane matrix systems versus conventional metal housing with nylon inserts in ball-retained mandibular implant overdentures

Objective: This study compared the retentive performance of two polyvinyl siloxane (PVS) matrix systems (retention.sil 400 and 600) versus conventional metal housing with nylon inserts in ball-retained mandibular overdentures.Methods: Thirty ball-retained overdenture models were allocated into three groups based on the attachment system material (n=10): Group 1, conventional metal housing with nylon inserts; Group 2, retention.sil 400; and Group 3, retention.sil 600. A total of 1440 insertion-removal cycles, simulating one year of clinical use, were conducted at 50 mm/sec using a universal testing machine. Retention forces were measured at baseline (0 cycles) and after 360, 720, 1080, and 1440 cycles. Statistical analyses were performed using one-way ANOVA, followed by post hoc Tukey's test at a significance level of P<0.05.Results: The conventional group showed the highest retention at all cycles. There were statistically significant differences in retention between the conventional group and both PVS groups at all cycles (P<0.001), but no significant differences were found between the two PVS groups (P>0.05). Absolute retention loss was significantly greater in the conventional metal housing with nylon inserts than in the two PVS groups (P<0.001). No significant difference was found in relative retention loss among the groups (P=0.108).Conclusions: Conventional metal housing with nylon inserts provided superior mean retention compared to the retention.sil 400 and retention.sil 600 matrix systems at all cycles, with no significant difference between the two PVS materials. The relative retention loss, however, did not significantly differ between the conventional group and PVS groups.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-03-01
DOI
https://doi.org/10.22038/jdmt.2025.82138.1709
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of retention in polyvinyl siloxane matrix systems versus conventional metal housing with nylon inserts in ball-retained mandibular implant overdentures

SHILAP Revista de lepidopterología
Dental Implant Techniques and Outcomes
article

Comparison of retention in polyvinyl siloxane matrix systems versus conventional metal housing with nylon inserts in ball-retained mandibular implant overdentures

article en

Abstract

Objective: This study compared the retentive performance of two polyvinyl siloxane (PVS) matrix systems (retention.sil 400 and 600) versus conventional metal housing with nylon inserts in ball-retained mandibular overdentures.Methods: Thirty ball-retained overdenture models were allocated into three groups based on the attachment system material (n=10): Group 1, conventional metal housing with nylon inserts; Group 2, retention.sil 400; and Group 3, retention.sil 600. A total of 1440 insertion-removal cycles, simulating one year of clinical use, were conducted at 50 mm/sec using a universal testing machine. Retention forces were measured at baseline (0 cycles) and after 360, 720, 1080, and 1440 cycles. Statistical analyses were performed using one-way ANOVA, followed by post hoc Tukey's test at a significance level of P<0.05.Results: The conventional group showed the highest retention at all cycles. There were statistically significant differences in retention between the conventional group and both PVS groups at all cycles (P<0.001), but no significant differences were found between the two PVS groups (P>0.05). Absolute retention loss was significantly greater in the conventional metal housing with nylon inserts than in the two PVS groups (P<0.001). No significant difference was found in relative retention loss among the groups (P=0.108).Conclusions: Conventional metal housing with nylon inserts provided superior mean retention compared to the retention.sil 400 and retention.sil 600 matrix systems at all cycles, with no significant difference between the two PVS materials. The relative retention loss, however, did not significantly differ between the conventional group and PVS groups.

SHILAP Revista de lepidopterología
Kamineni Institute of Dental Sciences (IN)
Sustainable cities and communities
Openalex Percentile: Top 40%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.