Effectiveness Of Type C Passive Filters In Reducing Harmonic Currents

This study aims to see how effective the type C passive filter is in reducing harmonic currents generated by the electrodynamometer induction motor trainer. The method used in this study is to model a C-type passive filter and simulate it with computer software. The type C passive filter modeling is designed to reduce harmonics in the thirty-fifth order. From the observation results, it was found that the thirty-fifth order harmonic current was 1.5% while the IEEE 519-2014 standard limits the thirty-fifth order harmonic current to 1.0%, which has exceeded the permitted standard. After the simulation, the type C passive filter successfully reduced the existing harmonics so that the harmonic content was 0.95%. From the results of this simulation, it can be concluded that the type C passive filter successfully reduced the harmonic content in the thirty-fifth order to 36.29%. This harmonic reduction has also been below the maximum value permitted by the IEEE 519 – 2014 standard at the thirty-fifth order so that the passive filter is effective in reducing the thirty-fifth harmonic produced by the electrodynamometer induction motor trainer.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-10-01
DOI
https://doi.org/10.24036/jtein.v5i2.728
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effectiveness Of Type C Passive Filters In Reducing Harmonic Currents

SHILAP Revista de lepidopterología
Power Quality and Harmonics
article

Effectiveness Of Type C Passive Filters In Reducing Harmonic Currents

article en

Abstract

This study aims to see how effective the type C passive filter is in reducing harmonic currents generated by the electrodynamometer induction motor trainer. The method used in this study is to model a C-type passive filter and simulate it with computer software. The type C passive filter modeling is designed to reduce harmonics in the thirty-fifth order. From the observation results, it was found that the thirty-fifth order harmonic current was 1.5% while the IEEE 519-2014 standard limits the thirty-fifth order harmonic current to 1.0%, which has exceeded the permitted standard. After the simulation, the type C passive filter successfully reduced the existing harmonics so that the harmonic content was 0.95%. From the results of this simulation, it can be concluded that the type C passive filter successfully reduced the harmonic content in the thirty-fifth order to 36.29%. This harmonic reduction has also been below the maximum value permitted by the IEEE 519 – 2014 standard at the thirty-fifth order so that the passive filter is effective in reducing the thirty-fifth harmonic produced by the electrodynamometer induction motor trainer.

SHILAP Revista de lepidopterología
State University of Medan (ID)
Affordable and clean energy
Openalex Percentile: Top 66%
Power Quality and Harmonics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.