Comparison of the dimensional accuracy of two polyvinyl siloxane putty-wash techniques and digital impressions for single implants adjacent to tooth crown preparations

Objective: This study compared the dimensional accuracy of two polyvinyl siloxane putty-wash impression techniques with the digital impression method for single implants adjacent to tooth crown preparations.Methods: Impressions were taken from a dental arch containing a full-metal preparation on the first molar adjacent to a Straumann tissue-level implant at the second premolar site. A laboratory scanner generated a standard tessellation language (STL) file as the reference for comparisons. Three methods were tested, each performed 10 times: (1) one-step putty-wash technique, (2) two-step putty-wash technique, and (3) digital impressions. Dimensional accuracy was assessed by measuring overall die dimensions, die height, die width, and the tooth-implant distance, using Geomagic Wrap software. Statistical analyses included one-way ANOVA and the Kruskal-Wallis test, with significance at P < 0.05.Results: No significant differences were found among the methods for the die height (P = 0.130), die width (P = 0.180), and tooth-implant distance (P = 0.486). However, the digital impression method showed significantly greater overall dimensional accuracy than the one-step putty-wash technique (P = 0.004). The two-step putty-wash method showed no significant difference with the one-step method or digital impressions concerning the overall die accuracy (P > 0.05).Conclusions: Digital impressions demonstrated significantly higher overall dimensional accuracy than the one-step putty-wash technique. Die height, die width, and tooth-implant distance were comparable across methods. Digital impressions are recommended for optimal accuracy when taking impressions from single implants adjacent to tooth crown preparations. The two-step putty-wash method offers a reliable alternative when digital tools are unavailable.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-12-01
DOI
https://doi.org/10.22038/jdmt.2024.82529.1714
Primary Topic
Cybernetics and Technology in Society
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of the dimensional accuracy of two polyvinyl siloxane putty-wash techniques and digital impressions for single implants adjacent to tooth crown preparations

SHILAP Revista de lepidopterología
Cybernetics and Technology in Society
article

Comparison of the dimensional accuracy of two polyvinyl siloxane putty-wash techniques and digital impressions for single implants adjacent to tooth crown preparations

article en

Abstract

Objective: This study compared the dimensional accuracy of two polyvinyl siloxane putty-wash impression techniques with the digital impression method for single implants adjacent to tooth crown preparations.Methods: Impressions were taken from a dental arch containing a full-metal preparation on the first molar adjacent to a Straumann tissue-level implant at the second premolar site. A laboratory scanner generated a standard tessellation language (STL) file as the reference for comparisons. Three methods were tested, each performed 10 times: (1) one-step putty-wash technique, (2) two-step putty-wash technique, and (3) digital impressions. Dimensional accuracy was assessed by measuring overall die dimensions, die height, die width, and the tooth-implant distance, using Geomagic Wrap software. Statistical analyses included one-way ANOVA and the Kruskal-Wallis test, with significance at P < 0.05.Results: No significant differences were found among the methods for the die height (P = 0.130), die width (P = 0.180), and tooth-implant distance (P = 0.486). However, the digital impression method showed significantly greater overall dimensional accuracy than the one-step putty-wash technique (P = 0.004). The two-step putty-wash method showed no significant difference with the one-step method or digital impressions concerning the overall die accuracy (P > 0.05).Conclusions: Digital impressions demonstrated significantly higher overall dimensional accuracy than the one-step putty-wash technique. Die height, die width, and tooth-implant distance were comparable across methods. Digital impressions are recommended for optimal accuracy when taking impressions from single implants adjacent to tooth crown preparations. The two-step putty-wash method offers a reliable alternative when digital tools are unavailable.

SHILAP Revista de lepidopterología
Openalex Percentile: Top 30%
Cybernetics and Technology in Society
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.