Diagnosing the type and location of the transformer fault by analyzing the dissolved gas using fuzzy logic

There are many methods to diagnose transformer faults, including dissolved gas analysis (DGA), done in two conventional and smart ways. This paper presents a new method based on fuzzy logic and 5 DGA methods (key gas method, Durenberg's ratio method, Rogerˊs ratio method, IEC method, and Duval triangle method) to evaluate the condition of power transformers. At first, it is determined whether the transformer is healthy or defective. This step is performed based on key gas methods and Durenberg's ratio method with a fuzzy logic approach. Then, if it is detected that the transformer is defective, the type of error is detected using Rogers and IEC methods. If the error detection by these two methods reaches the same result, the error type detection is terminated and if the result is not the same, the Duval triangle method with fuzzy logic approach is used to detect the error type. The presented algorithm has been tested on 30 transformer devices and the results confirm its high accuracy (96.7%) in fault detection. In this article, in addition to detecting the type of fault, the location of the fault has been investigated and diagnosed using the CO2/CO ratio and the key gas method with a fuzzy logic approach.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-09-01
DOI
https://doi.org/10.22108/isee.2024.140046.1670
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnosing the type and location of the transformer fault by analyzing the dissolved gas using fuzzy logic

SHILAP Revista de lepidopterología
Power Transformer Diagnostics and Insulation
article

Diagnosing the type and location of the transformer fault by analyzing the dissolved gas using fuzzy logic

article en

Abstract

There are many methods to diagnose transformer faults, including dissolved gas analysis (DGA), done in two conventional and smart ways. This paper presents a new method based on fuzzy logic and 5 DGA methods (key gas method, Durenberg's ratio method, Rogerˊs ratio method, IEC method, and Duval triangle method) to evaluate the condition of power transformers. At first, it is determined whether the transformer is healthy or defective. This step is performed based on key gas methods and Durenberg's ratio method with a fuzzy logic approach. Then, if it is detected that the transformer is defective, the type of error is detected using Rogers and IEC methods. If the error detection by these two methods reaches the same result, the error type detection is terminated and if the result is not the same, the Duval triangle method with fuzzy logic approach is used to detect the error type. The presented algorithm has been tested on 30 transformer devices and the results confirm its high accuracy (96.7%) in fault detection. In this article, in addition to detecting the type of fault, the location of the fault has been investigated and diagnosed using the CO2/CO ratio and the key gas method with a fuzzy logic approach.

SHILAP Revista de lepidopterología
Openalex Percentile: Top 66%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Diagnosing the type and location of the transformer fault by analyzing the dissolved gas using fuzzy logic · SHILAP Revista de lepidopterología (2024) | TGRS Research Map | TGRS