Differential current protection for active distribution networks with dual proportional compensation coefficients

The increasing penetration of distributed generation (DG) in distribution networks has exposed poor adaptation of conventional differential current protection schemes. To address this issue, an analysis of the positive-sequence current components output by various types of DGs during faults is conducted. A differential current protection scheme for active distribution networks with dual proportional compensation coefficients is proposed. The scheme constructs braking coefficients and compensation coefficients for fault current phasors, adjusting the phase and magnitude of the positive-sequence current fault components on both sides. This adjustment helps the positive-sequence current components move more easily into the action region of the amplitude-phase plane during internal faults, while ensuring reliable non-operation during external faults. Finally, the proposed protection scheme’s effectiveness under different fault conditions is tested using a model of an active distribution network established in PSCAD/EMTDC. The simulation results demonstrate that the proposed scheme improves both the sensitivity and reliability of differential current protection.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-12-01
DOI
https://doi.org/10.19585/j.zjdl.202412011
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Differential current protection for active distribution networks with dual proportional compensation coefficients

SHILAP Revista de lepidopterología
Power Systems Fault Detection
article

Differential current protection for active distribution networks with dual proportional compensation coefficients

article en

Abstract

The increasing penetration of distributed generation (DG) in distribution networks has exposed poor adaptation of conventional differential current protection schemes. To address this issue, an analysis of the positive-sequence current components output by various types of DGs during faults is conducted. A differential current protection scheme for active distribution networks with dual proportional compensation coefficients is proposed. The scheme constructs braking coefficients and compensation coefficients for fault current phasors, adjusting the phase and magnitude of the positive-sequence current fault components on both sides. This adjustment helps the positive-sequence current components move more easily into the action region of the amplitude-phase plane during internal faults, while ensuring reliable non-operation during external faults. Finally, the proposed protection scheme’s effectiveness under different fault conditions is tested using a model of an active distribution network established in PSCAD/EMTDC. The simulation results demonstrate that the proposed scheme improves both the sensitivity and reliability of differential current protection.

SHILAP Revista de lepidopterología
Openalex Percentile: Top 56%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Differential current protection for active distribution networks with dual proportional compensation coefficients · SHILAP Revista de lepidopterología (2024) | TGRS Research Map | TGRS