Research of hot spot temperature calculation in oil-immersed transformer based on modified thermal model

The hottest spot temperature (HST) of windings of oil-immersed transformer is an important factor that affects load capacity and operation life of transformer, and is closely related to the transformer load, top oil and environment temperature. Higher hot spot temperature, when operating at high temperature and overload, may lead to transformer failure, which will affect the normal operation of the power system. In order to accurately calculate the hot spot temperature of transformer winding, we construct the dynamic thermal model of transformer based on the theory of heat transfer and thermal-electrical analogy, and then, built a set of differential equations. By taking the effect of heat transfer coefficient of heat sink is different from inside to outside into consideration, we get the effective cooling area of transformer, and fix the thermal circuit model. Taking a 180 MVA-220 kV transformer of Tianwei transformer factory in Hefei as an example, we establish the thermal circuit model to calculate the hot spot temperature. Meanwhile, we establish a three-dimensional model, and get its internal temperature distribution based on Fluent simulation software. Finally, we carry out a temperature rise test on the main transformer of this main transformer winding, and the hot spot temperature data of winding is obtained. Combined with online monitored values, we compare and analyze the accuracy of thermal model and the model calculation results recommended by IEEE guidelines. The results show that the thermal circuit model with higher accuracy relative to the IEEE guidelines model, which proves that the fixed model can accurately calculate the hot spot temperature of oil-immersed transformer.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-03-01
DOI
https://doi.org/10.19753/j.issn1001-1390.2025.03.010
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research of hot spot temperature calculation in oil-immersed transformer based on modified thermal model

SHILAP Revista de lepidopterología
Power Transformer Diagnostics and Insulation
article

Research of hot spot temperature calculation in oil-immersed transformer based on modified thermal model

article en

Abstract

The hottest spot temperature (HST) of windings of oil-immersed transformer is an important factor that affects load capacity and operation life of transformer, and is closely related to the transformer load, top oil and environment temperature. Higher hot spot temperature, when operating at high temperature and overload, may lead to transformer failure, which will affect the normal operation of the power system. In order to accurately calculate the hot spot temperature of transformer winding, we construct the dynamic thermal model of transformer based on the theory of heat transfer and thermal-electrical analogy, and then, built a set of differential equations. By taking the effect of heat transfer coefficient of heat sink is different from inside to outside into consideration, we get the effective cooling area of transformer, and fix the thermal circuit model. Taking a 180 MVA-220 kV transformer of Tianwei transformer factory in Hefei as an example, we establish the thermal circuit model to calculate the hot spot temperature. Meanwhile, we establish a three-dimensional model, and get its internal temperature distribution based on Fluent simulation software. Finally, we carry out a temperature rise test on the main transformer of this main transformer winding, and the hot spot temperature data of winding is obtained. Combined with online monitored values, we compare and analyze the accuracy of thermal model and the model calculation results recommended by IEEE guidelines. The results show that the thermal circuit model with higher accuracy relative to the IEEE guidelines model, which proves that the fixed model can accurately calculate the hot spot temperature of oil-immersed transformer.

SHILAP Revista de lepidopterología
North China Electric Power University (CN), State Grid Corporation of China (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 55%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.