"Application of halogen moisture meter in volatile content measurement of nitrile rubber"

The volatile content in nitrile rubber was measured by halogen moisture meter and compared with the results obtained by the hot-roll method. The influence of different measurement conditions on the measured results of the halogen moisture meter was investigated. The results showed that using the halogen moisture meter, the volatile content in nitrile rubber raw rubber could be measured by both the preset drying time method and preset mass loss method. Under suitable conditions such as sample mass of 3 g, drying temperature of 110 ℃, preset heating time of 8 min, or preset mass loss of 1/140 mg/s, the measured results were consistent with the hot-roll method. This method reduced measure time, was easy to operate, and could be used to guide quickly actual production.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-12-01
DOI
https://doi.org/10.19908/j.cnki.issn1000-1255.2023.06.0504
Primary Topic
Polymer Science and PVC
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

"Application of halogen moisture meter in volatile content measurement of nitrile rubber"

SHILAP Revista de lepidopterología
Polymer Science and PVC
article

"Application of halogen moisture meter in volatile content measurement of nitrile rubber"

article en

Abstract

The volatile content in nitrile rubber was measured by halogen moisture meter and compared with the results obtained by the hot-roll method. The influence of different measurement conditions on the measured results of the halogen moisture meter was investigated. The results showed that using the halogen moisture meter, the volatile content in nitrile rubber raw rubber could be measured by both the preset drying time method and preset mass loss method. Under suitable conditions such as sample mass of 3 g, drying temperature of 110 ℃, preset heating time of 8 min, or preset mass loss of 1/140 mg/s, the measured results were consistent with the hot-roll method. This method reduced measure time, was easy to operate, and could be used to guide quickly actual production.

SHILAP Revista de lepidopterología
Lanzhou Petrochemical Polytechnic (CN)
Openalex Percentile: Top 70%
Polymer Science and PVC
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.