Circulating current suppression strategy for VSG parallel system with island microgrid

In low-voltage microgrid, the space span between distributed generators is large, and the difference of line impedance has a great impact on the current sharing effect of inverter parallel system controlled by traditional virtual synchronous generator (VSG). The relationship between circulating current and power distribution and the influence of line impedance on power distribution are analyzed. On this basis, a circulating current suppression strategy of inverter parallel system based on virtual synchronous generator is proposed. In this strategy, the transmission power is introduced into the power control loop, and the bus voltage negative feedback and integral link are introduced into the reactive power voltage loop to realize the current sharing control under the condition of line impedance mismatch in the steady state. Then, by setting parameters and introducing virtual impedance, the circulation of dynamic process is reduced, and the system obtains good dynamic characteristics. Finally, MATLAB/Simulink simulation platform is used to verify the effectiveness of the proposed strategy.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-04-01
DOI
https://doi.org/10.19753/j.issn1001-1390.2025.04.015
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Circulating current suppression strategy for VSG parallel system with island microgrid

SHILAP Revista de lepidopterología
Microgrid Control and Optimization
article

Circulating current suppression strategy for VSG parallel system with island microgrid

article en

Abstract

In low-voltage microgrid, the space span between distributed generators is large, and the difference of line impedance has a great impact on the current sharing effect of inverter parallel system controlled by traditional virtual synchronous generator (VSG). The relationship between circulating current and power distribution and the influence of line impedance on power distribution are analyzed. On this basis, a circulating current suppression strategy of inverter parallel system based on virtual synchronous generator is proposed. In this strategy, the transmission power is introduced into the power control loop, and the bus voltage negative feedback and integral link are introduced into the reactive power voltage loop to realize the current sharing control under the condition of line impedance mismatch in the steady state. Then, by setting parameters and introducing virtual impedance, the circulation of dynamic process is reduced, and the system obtains good dynamic characteristics. Finally, MATLAB/Simulink simulation platform is used to verify the effectiveness of the proposed strategy.

SHILAP Revista de lepidopterología
Changsha University of Science and Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 47%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.