The reference window for reduced perturbation of the reference wave in electrical biasing off-axis electron holography

The perturbation of the reference wave due to electric stray fields represents a major challenge in quantitative electron holographic investigations. By introducing a focused-ion-beam-milled rectangular hole, the reference window, in an area of nearly constant electrostatic potential of the sample, this perturbation can be significantly reduced. The edge of the window forms a closed conducting loop, acting similarly to a Faraday cage, shielding the influence of the stray field on the reference wave to some extent. In this work, the shielding effect of the reference window is systematically investigated by comparing electron holograms of an electrically biased coplanar capacitor, as a well-known reference sample, with finite element simulations. It is shown that the introduction of the reference window into electrical biasing samples both suppresses unknown lateral phase distortions substantially and in addition improves the agreement of the experimentally observed phase slope with that expected by simulation significantly, particularly for small object-reference wave distances. Consequently, a slight adjustment of the sample geometry results in an improved reproducibility of electron holographic electrical biasing experiments, which is a significant step towards quantitative evaluation.

Publication Details

Journal
edoc Publication server (Humboldt University of Berlin)
Published
2024-10-11
DOI
https://doi.org/10.18452/32985
Primary Topic
Advanced Electron Microscopy Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The reference window for reduced perturbation of the reference wave in electrical biasing off-axis electron holography

edoc Publication server (Humboldt University of Berlin)
Advanced Electron Microscopy Techniques and Applications
article

The reference window for reduced perturbation of the reference wave in electrical biasing off-axis electron holography

article en

Abstract

The perturbation of the reference wave due to electric stray fields represents a major challenge in quantitative electron holographic investigations. By introducing a focused-ion-beam-milled rectangular hole, the reference window, in an area of nearly constant electrostatic potential of the sample, this perturbation can be significantly reduced. The edge of the window forms a closed conducting loop, acting similarly to a Faraday cage, shielding the influence of the stray field on the reference wave to some extent. In this work, the shielding effect of the reference window is systematically investigated by comparing electron holograms of an electrically biased coplanar capacitor, as a well-known reference sample, with finite element simulations. It is shown that the introduction of the reference window into electrical biasing samples both suppresses unknown lateral phase distortions substantially and in addition improves the agreement of the experimentally observed phase slope with that expected by simulation significantly, particularly for small object-reference wave distances. Consequently, a slight adjustment of the sample geometry results in an improved reproducibility of electron holographic electrical biasing experiments, which is a significant step towards quantitative evaluation.

edoc Publication server (Humboldt University of Berlin)
Openalex Percentile: Top 65%
Advanced Electron Microscopy Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The reference window for reduced perturbation of the reference wave in electrical biasing off-axis electron holography · edoc Publication server (Humboldt University of Berlin) (2024) | TGRS Research Map | TGRS