Certification testing of prototype superconducting quarter-wave and half-wave resonators for HIAF

The 81.25 MHz quarter-wave resonator (QWR) and 162.5 MHz half-wave resonator (HWR) are selected as the main accelerating cavities for the superconducting ion linac of the High Intensity heavy-ion Accelerator Facility (HIAF) at the Institute of Modern Physics (IMP). Six QWR007 (βopt = 0.07) cavities and eight HWR015 (βopt = 0.15) cavities have been fabricated before the mass production to verify the design and production quality control. Two cavities of the both types have been random chosen to surface processing and vertical testing for performance validating before welding helium vessel. In this paper, the development of SRF cavity for HIAF will be addressed, which including the fabrication, surface processing and vertical testing results. The achieved gradients for both cavities have exceeded 60%~100% of requiring operation gradients. The Q0 of both types cavities have met the 2 K operation requirement too. These results inspired to push the cavity production for the HIAF project forward to the mass production stage.

Publication Details

Journal
JACOW
Published
2024-12-18
DOI
https://doi.org/10.18429/jacow-ibic2024-tup66
Primary Topic
Particle accelerators and beam dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Certification testing of prototype superconducting quarter-wave and half-wave resonators for HIAF

JACOW
Particle accelerators and beam dynamics
article

Certification testing of prototype superconducting quarter-wave and half-wave resonators for HIAF

article en

Abstract

The 81.25 MHz quarter-wave resonator (QWR) and 162.5 MHz half-wave resonator (HWR) are selected as the main accelerating cavities for the superconducting ion linac of the High Intensity heavy-ion Accelerator Facility (HIAF) at the Institute of Modern Physics (IMP). Six QWR007 (βopt = 0.07) cavities and eight HWR015 (βopt = 0.15) cavities have been fabricated before the mass production to verify the design and production quality control. Two cavities of the both types have been random chosen to surface processing and vertical testing for performance validating before welding helium vessel. In this paper, the development of SRF cavity for HIAF will be addressed, which including the fabrication, surface processing and vertical testing results. The achieved gradients for both cavities have exceeded 60%~100% of requiring operation gradients. The Q0 of both types cavities have met the 2 K operation requirement too. These results inspired to push the cavity production for the HIAF project forward to the mass production stage.

JACOW
Openalex Percentile: Top 35%
Particle accelerators and beam dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.