First proof-of-concept transverse beam profile measurements with gas jet in-vivo dose profiler for medical accelerators

To ensure patient safety, treatment efficacy, and facility efficiency, a full online characterisation of the charged particle beam is required for every ion beam therapy facility. Current dosimetry methods offer limited information or are invasive to the beam, asking for the development of in-vivo dosimetry solutions. The QUASAR Group, based at Cockcroft Institute in the UK, has been developing non-invasive beam monitor for medical accelerators since 2015. Detailed transverse beam profile monitoring is the first step towards in-vivo dosimetry. The current monitor applies a supersonic beam gas curtain, interacting with a charged particle beam to then exploit the resulting impact ionization to record the transverse beam profile. A prototype monitor was tested at Dalton Cumbrian Facility’s pelletron accelerator for proof-of-concept beam measurements in summer 2023. The measurements were carried out for different beam energies, sizes and intensities and with both, proton and carbon ion beams. This contribution presents the monitor design and functioning principle, results from the experimental campaign, and planned upgrades to achieve real-time, non-invasive dosimetry.

Publication Details

Journal
JACOW
Published
2024-12-18
DOI
https://doi.org/10.18429/jacow-ibic2024-webc3
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

First proof-of-concept transverse beam profile measurements with gas jet in-vivo dose profiler for medical accelerators

JACOW
Radiation Therapy and Dosimetry
article

First proof-of-concept transverse beam profile measurements with gas jet in-vivo dose profiler for medical accelerators

article en

Abstract

To ensure patient safety, treatment efficacy, and facility efficiency, a full online characterisation of the charged particle beam is required for every ion beam therapy facility. Current dosimetry methods offer limited information or are invasive to the beam, asking for the development of in-vivo dosimetry solutions. The QUASAR Group, based at Cockcroft Institute in the UK, has been developing non-invasive beam monitor for medical accelerators since 2015. Detailed transverse beam profile monitoring is the first step towards in-vivo dosimetry. The current monitor applies a supersonic beam gas curtain, interacting with a charged particle beam to then exploit the resulting impact ionization to record the transverse beam profile. A prototype monitor was tested at Dalton Cumbrian Facility’s pelletron accelerator for proof-of-concept beam measurements in summer 2023. The measurements were carried out for different beam energies, sizes and intensities and with both, proton and carbon ion beams. This contribution presents the monitor design and functioning principle, results from the experimental campaign, and planned upgrades to achieve real-time, non-invasive dosimetry.

JACOW
Openalex Percentile: Top 47%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

First proof-of-concept transverse beam profile measurements with gas jet in-vivo dose profiler for medical accelerators · JACOW (2024) | TGRS Research Map | TGRS