Prospective study on quantitative evaluation of femoral neck bone mineral density using spectral localizer radiograph from photon-counting detector CT

Objective To evaluate the performance of spectral localizer radiograph (SLR) acquired by photon-counting detector CT (PCD-CT) for the quantitative assessment of areal bone mineral density (aBMD) in the femoral neck. Methods From July 2024 to April 2025, subjects (≥18 years old) scheduled for both dual-energy X-ray absorptiometry (DXA) and CT scans were prospectively enrolled. All subjects underwent PCD-CT examinations to obtain SLR, and two observers independently performed blinded measurements of the aBMD in the left femoral neck on the SLR. The measurement results of DXA were used as the reference standard to evaluate the quantitative accuracy of SLR for aBMD and its diagnostic performance for abnormal bone mass (T-score<-1.0). Results A total of 63 subjects (36 females) were enrolled, with a mean age of 64.30±13.20 years. The median aBMD measured by DXA was 0.889 [interquartile range (IQR), 0.749-1.031] g/cm2, and 23 subjects (36.51%) showed abnormal bone mass. The aBMD values measured by the two observers were 0.879 (0.760-0.985) g/cm2 and 0.891 (0.784-0.977) g/cm2, respectively. SLR-based measurements of aBMD demonstrated excellent inter-observer agreement (intraclass correlation coefficient = 0.98). Using DXA results as the reference, the median absolute percentage error of aBMD measured by SLR was 6.66% (IQR, 3.64%-9.80%). The diagnostic accuracy, sensitivity, and specificity of SLR for diagnosing abnormal bone mass were 95.24% (50/63), 95.65% (22/23), and 95.00% (38/40), respectively. Conclusions Spectral localizer radiographs acquired by PCD-CT can accurately quantify bone mineral density in the femoral neck and demonstrate high diagnostic performance for abnormal bone mass.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-04-01
DOI
https://doi.org/10.16150/j.1671-2870.2025.02.007
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Prospective study on quantitative evaluation of femoral neck bone mineral density using spectral localizer radiograph from photon-counting detector CT

SHILAP Revista de lepidopterología
Advanced X-ray and CT Imaging
article

Prospective study on quantitative evaluation of femoral neck bone mineral density using spectral localizer radiograph from photon-counting detector CT

article en

Abstract

Objective To evaluate the performance of spectral localizer radiograph (SLR) acquired by photon-counting detector CT (PCD-CT) for the quantitative assessment of areal bone mineral density (aBMD) in the femoral neck. Methods From July 2024 to April 2025, subjects (≥18 years old) scheduled for both dual-energy X-ray absorptiometry (DXA) and CT scans were prospectively enrolled. All subjects underwent PCD-CT examinations to obtain SLR, and two observers independently performed blinded measurements of the aBMD in the left femoral neck on the SLR. The measurement results of DXA were used as the reference standard to evaluate the quantitative accuracy of SLR for aBMD and its diagnostic performance for abnormal bone mass (T-score<-1.0). Results A total of 63 subjects (36 females) were enrolled, with a mean age of 64.30±13.20 years. The median aBMD measured by DXA was 0.889 [interquartile range (IQR), 0.749-1.031] g/cm2, and 23 subjects (36.51%) showed abnormal bone mass. The aBMD values measured by the two observers were 0.879 (0.760-0.985) g/cm2 and 0.891 (0.784-0.977) g/cm2, respectively. SLR-based measurements of aBMD demonstrated excellent inter-observer agreement (intraclass correlation coefficient = 0.98). Using DXA results as the reference, the median absolute percentage error of aBMD measured by SLR was 6.66% (IQR, 3.64%-9.80%). The diagnostic accuracy, sensitivity, and specificity of SLR for diagnosing abnormal bone mass were 95.24% (50/63), 95.65% (22/23), and 95.00% (38/40), respectively. Conclusions Spectral localizer radiographs acquired by PCD-CT can accurately quantify bone mineral density in the femoral neck and demonstrate high diagnostic performance for abnormal bone mass.

SHILAP Revista de lepidopterología
Ruijin Hospital (CN)
Openalex Percentile: Top 55%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.