Research and Application of Corrosion and Scaling Prevention Strategies for Long-Distance Heating Pipe Network with Large Temperature Difference

Ningxia A Heat Supply Company adopted the large temperature difference long-distance heating technology.During two consecutive heating seasons from 2019 to 2021, significant scaling, pitting corrosion of stainless steel and corrosion of carbon steel were observed in the secondary pipeline network, which severely impacted the heating effect for residents during the winter.The heat supply company conducted research and development on scale and corrosion inhibitors,as well as studies on the critical conditions for pitting corrosion,based on the characteristics of its water quality and operating conditions.Ultimately, an anti-corrosion and anti-scaling strategy centered on the addition of TC-type scale and corrosion inhibitors was determined.Through industrial trials, random inspections of the heat exchanger plates revealed no significant pitting or scaling, and the results of carbon steel corrosion coupon tests indicated that the corrosion rate of the inner pipeline walls was effectively controlled.This ensured the safe and economical operation of the heating system.The corrosion and scale prevention strategy has shown great potential for broader application in the same type of heating systems.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-09-01
DOI
https://doi.org/10.16577/j.issn.1001-1560.2024.0214
Primary Topic
Geothermal Energy Systems and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research and Application of Corrosion and Scaling Prevention Strategies for Long-Distance Heating Pipe Network with Large Temperature Difference

SHILAP Revista de lepidopterología
Geothermal Energy Systems and Applications
article

Research and Application of Corrosion and Scaling Prevention Strategies for Long-Distance Heating Pipe Network with Large Temperature Difference

article en

Abstract

Ningxia A Heat Supply Company adopted the large temperature difference long-distance heating technology.During two consecutive heating seasons from 2019 to 2021, significant scaling, pitting corrosion of stainless steel and corrosion of carbon steel were observed in the secondary pipeline network, which severely impacted the heating effect for residents during the winter.The heat supply company conducted research and development on scale and corrosion inhibitors,as well as studies on the critical conditions for pitting corrosion,based on the characteristics of its water quality and operating conditions.Ultimately, an anti-corrosion and anti-scaling strategy centered on the addition of TC-type scale and corrosion inhibitors was determined.Through industrial trials, random inspections of the heat exchanger plates revealed no significant pitting or scaling, and the results of carbon steel corrosion coupon tests indicated that the corrosion rate of the inner pipeline walls was effectively controlled.This ensured the safe and economical operation of the heating system.The corrosion and scale prevention strategy has shown great potential for broader application in the same type of heating systems.

SHILAP Revista de lepidopterología
Thermal Power Research Institute (CN)
Openalex Percentile: Top 75%
Geothermal Energy Systems and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.