Optimization of the Operating Point of Multi-Reactive Power Compensation Equipment Considering Facility Characteristics

Increased integration of renewable energy sources, which are typically inverter-based, has heightened concerns about voltage stability in power systems. This paper presents an optimization strategy for the operating points of reactive power compensation equipment, specifically Flexible AC Transmission Systems (FACTS) and fixed shunt capacitors, to enhance voltage stability. The proposed method employs QV sensitivity to linearize the relationship between reactive power and voltage, formulating the optimization problem as a Mixed Integer Quadratic Programming (MIQP) problem. By leveraging the unique characteristics of FACTS and shunt devices, the method aims to minimize voltage deviations and reactive power imbalance without extensive power flow calculations. Simulation results on the IEEE 39-bus system demonstrate the effectiveness of the proposed strategy in maintaining voltage stability and optimizing the reactive power response under various loading conditions.

Institutions

Publication Details

Published
2024-12-01
DOI
https://doi.org/10.1109/tencon61640.2024.10902882
Primary Topic
Mycorrhizal Fungi and Plant Interactions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of the Operating Point of Multi-Reactive Power Compensation Equipment Considering Facility Characteristics

Mycorrhizal Fungi and Plant Interactions
article

Optimization of the Operating Point of Multi-Reactive Power Compensation Equipment Considering Facility Characteristics

article en

Abstract

Increased integration of renewable energy sources, which are typically inverter-based, has heightened concerns about voltage stability in power systems. This paper presents an optimization strategy for the operating points of reactive power compensation equipment, specifically Flexible AC Transmission Systems (FACTS) and fixed shunt capacitors, to enhance voltage stability. The proposed method employs QV sensitivity to linearize the relationship between reactive power and voltage, formulating the optimization problem as a Mixed Integer Quadratic Programming (MIQP) problem. By leveraging the unique characteristics of FACTS and shunt devices, the method aims to minimize voltage deviations and reactive power imbalance without extensive power flow calculations. Simulation results on the IEEE 39-bus system demonstrate the effectiveness of the proposed strategy in maintaining voltage stability and optimizing the reactive power response under various loading conditions.

Kwangwoon University (KR), Korea Electric Power Corporation (South Korea) (KR)
Affordable and clean energy
Openalex Percentile: Top 54%
Mycorrhizal Fungi and Plant Interactions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Optimization of the Operating Point of Multi-Reactive Power Compensation Equipment Considering Facility Characteristics · (2024) | TGRS Research Map | TGRS