Advancing Optical Coherence Tomography through Opto-Electronic Frequency Shifting

\nOptical Coherence Tomography (OCT) stands out for its ability to combine the high resolution of microscopy with the penetration-depth of clinical imaging. However, in practice this is still limited to a few millimetres. Interestingly, the imaging-depth of the latest swept-source systems is not limited by their spectral width but by the analog-to-digital sampling rate. In lieu of slow reference arm length adjustments, we leverage opto-electronic frequency shifting. This allows for depth adjustments on the microsecond timescale and a modest detector bandwidth of 200MHz. The opto-electronic scheme immediately gives us access to an 8mm range, a fourfold increase over the nominal 2mm range of the source. Moreover, by circumventing the need for a mechanical reference arm, changes in the axial displacement of the sample can be compensated in real-time. This makes it attractive for imaging arbitrarily-curved surfaces. We showcase this with wide-field OCT imaging of the curved retina.\n

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2024-10-31
DOI
https://doi.org/10.1051/epjconf/202430904003/pdf
Primary Topic
Mycorrhizal Fungi and Plant Interactions
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Advancing Optical Coherence Tomography through Opto-Electronic Frequency Shifting

Springer Link (Chiba Institute of Technology)
Mycorrhizal Fungi and Plant Interactions
article

Advancing Optical Coherence Tomography through Opto-Electronic Frequency Shifting

article en

Abstract

\nOptical Coherence Tomography (OCT) stands out for its ability to combine the high resolution of microscopy with the penetration-depth of clinical imaging. However, in practice this is still limited to a few millimetres. Interestingly, the imaging-depth of the latest swept-source systems is not limited by their spectral width but by the analog-to-digital sampling rate. In lieu of slow reference arm length adjustments, we leverage opto-electronic frequency shifting. This allows for depth adjustments on the microsecond timescale and a modest detector bandwidth of 200MHz. The opto-electronic scheme immediately gives us access to an 8mm range, a fourfold increase over the nominal 2mm range of the source. Moreover, by circumventing the need for a mechanical reference arm, changes in the axial displacement of the sample can be compensated in real-time. This makes it attractive for imaging arbitrarily-curved surfaces. We showcase this with wide-field OCT imaging of the curved retina.\n

Springer Link (Chiba Institute of Technology)
UK Research and Innovation, Engineering and Physical Sciences Research Council
Openalex Percentile: Top 58%
Mycorrhizal Fungi and Plant Interactions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.