Sensitization effects of CR-39 neutron dosimeters pre-treated with CO2 under various pressures and durations

BackgroundEtched track dosimeters (ETDs) based on CR-39 foils are the most frequently used passive detectors for neutron personal dosimetry at various nuclear facilities. That applying a pre-treatment in carbon dioxide (hereafter, CO2 pre-treatment) can improve the CR-39 detection sensitivity and enlarge the tracks is extremely valuable and warrants further investigation.PurposeThis study aims to investigate the effect of CO2 pre-treatment on the sensitivity and the track size distributions of CR-39 detectors, and to obtain an optimal CO2 pre-treatment condition.MethodsA parametric study was conducted to evaluate the effect of CO2 pre-treatments at different pressures and durations on CR-39 detectors. The detectors were firstly irradiated by a standard 252Cf neutron source, delivering a personal dose equivalent Hp(10) of 2 mSv. Then, the detectors were subjected to carbon dioxide treatment prior to undergoing chemical etching for durations ranging from 6 h to 168 h at partial pressures varying between 0.1 MPa to 1.6 MPa. Finally, the correlation between detector sensitivity and pre-treatment condition was obtained by analyzing the number of registered tracks and track size distribution under each pre-treatment condition.ResultsThe obtained results indicate that the CO2 pre-treatment significantly improves sensitivity and maximum track size, with the sensitivity increasing by up to 870% and the maximum track size expanding from 20 μm to 40 μm. The sensitivity increases linearly with pre-treatment pressures, and the saturation point of the maximum track size appears around 40 μm. As the time and pressure continue to increase, the neutron spectrometry information contained in the track size distributions will be erased, the optimal sensitivity for CR-39 to retain the spectral information in the track size distributions is 6.25 tracks·mm-2·mSv-1.ConclusionsThis study is of significance for improving the sensitivity of CR-39 detectors in neutron dosimetry and selecting CO2 pre-treatment conditions, providing a processing method to enhance the track readability whilst preserving the spectral information in the track distributions for practical applications of CR-39 detectors in neutron dosimetry and spectrometry.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-10-01
DOI
https://doi.org/10.11889/j.0253-3219.2024.hjs.47.100404
Primary Topic
Mycorrhizal Fungi and Plant Interactions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sensitization effects of CR-39 neutron dosimeters pre-treated with CO2 under various pressures and durations

SHILAP Revista de lepidopterología
Mycorrhizal Fungi and Plant Interactions
article

Sensitization effects of CR-39 neutron dosimeters pre-treated with CO2 under various pressures and durations

article en

Abstract

BackgroundEtched track dosimeters (ETDs) based on CR-39 foils are the most frequently used passive detectors for neutron personal dosimetry at various nuclear facilities. That applying a pre-treatment in carbon dioxide (hereafter, CO2 pre-treatment) can improve the CR-39 detection sensitivity and enlarge the tracks is extremely valuable and warrants further investigation.PurposeThis study aims to investigate the effect of CO2 pre-treatment on the sensitivity and the track size distributions of CR-39 detectors, and to obtain an optimal CO2 pre-treatment condition.MethodsA parametric study was conducted to evaluate the effect of CO2 pre-treatments at different pressures and durations on CR-39 detectors. The detectors were firstly irradiated by a standard 252Cf neutron source, delivering a personal dose equivalent Hp(10) of 2 mSv. Then, the detectors were subjected to carbon dioxide treatment prior to undergoing chemical etching for durations ranging from 6 h to 168 h at partial pressures varying between 0.1 MPa to 1.6 MPa. Finally, the correlation between detector sensitivity and pre-treatment condition was obtained by analyzing the number of registered tracks and track size distribution under each pre-treatment condition.ResultsThe obtained results indicate that the CO2 pre-treatment significantly improves sensitivity and maximum track size, with the sensitivity increasing by up to 870% and the maximum track size expanding from 20 μm to 40 μm. The sensitivity increases linearly with pre-treatment pressures, and the saturation point of the maximum track size appears around 40 μm. As the time and pressure continue to increase, the neutron spectrometry information contained in the track size distributions will be erased, the optimal sensitivity for CR-39 to retain the spectral information in the track size distributions is 6.25 tracks·mm-2·mSv-1.ConclusionsThis study is of significance for improving the sensitivity of CR-39 detectors in neutron dosimetry and selecting CO2 pre-treatment conditions, providing a processing method to enhance the track readability whilst preserving the spectral information in the track distributions for practical applications of CR-39 detectors in neutron dosimetry and spectrometry.

SHILAP Revista de lepidopterología
Openalex Percentile: Top 58%
Mycorrhizal Fungi and Plant Interactions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Sensitization effects of CR-39 neutron dosimeters pre-treated with CO2 under various pressures and durations · SHILAP Revista de lepidopterología (2024) | TGRS Research Map | TGRS