Analyzing DC Partial Discharge Characteristics of Voids Defect in MVDC Switchboard Cable Terminations

In DC power equipment, the switchboard is connected via a termination when the cable is connected from the outside. In the termination, multilayer interfaces are formed between XLPE and semi-conductive layer. Void defects occur between the multilayer interfaces due to various causes during cable connection, which causes damage due to partial discharge inside the termination. Therefore, this paper simulates the multilayer interface of XLPE-semi-conductive layer of switchboard cable termination to fabricated partial discharge simulation defect electrodes, and experiments were conducted under three different conditions by varying the size of the voids. The experiments were conducted at a temperature of 70 ° C to account for the rising temperature conditions at termination during operation. The discharge magnitude increases proportionally with both applied voltage and void size. In addition, discharges are larger and more frequently proportional to the applied voltage and void size. The characteristics of void partial discharges show that over time, the occurrence frequency increases, ceases at a certain point, and then increases again.

Institutions

Publication Details

Published
2024-10-06
DOI
https://doi.org/10.1109/ceidp61745.2024.10907315
Primary Topic
Mycorrhizal Fungi and Plant Interactions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analyzing DC Partial Discharge Characteristics of Voids Defect in MVDC Switchboard Cable Terminations

Mycorrhizal Fungi and Plant Interactions
article

Analyzing DC Partial Discharge Characteristics of Voids Defect in MVDC Switchboard Cable Terminations

article en

Abstract

In DC power equipment, the switchboard is connected via a termination when the cable is connected from the outside. In the termination, multilayer interfaces are formed between XLPE and semi-conductive layer. Void defects occur between the multilayer interfaces due to various causes during cable connection, which causes damage due to partial discharge inside the termination. Therefore, this paper simulates the multilayer interface of XLPE-semi-conductive layer of switchboard cable termination to fabricated partial discharge simulation defect electrodes, and experiments were conducted under three different conditions by varying the size of the voids. The experiments were conducted at a temperature of 70 ° C to account for the rising temperature conditions at termination during operation. The discharge magnitude increases proportionally with both applied voltage and void size. In addition, discharges are larger and more frequently proportional to the applied voltage and void size. The characteristics of void partial discharges show that over time, the occurrence frequency increases, ceases at a certain point, and then increases again.

Korea Electric Power Corporation (South Korea) (KR), Hanyang University (KR)
Affordable and clean energy
Openalex Percentile: Top 58%
Mycorrhizal Fungi and Plant Interactions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.