Molecular Insightsinto the Effects of Cushion Gason Underground Hydrogen Storage

In underground hydrogen storage (UHS), a cushion gas is commonly used to provide pressure support to assist the withdrawal of hydrogen. Molecular dynamics (MD) simulations of the H<sub>2</sub> + cushion gas + water ternary system were conducted at 323–448 K and 20–150 MPa. We considered N<sub>2</sub>, CH<sub>4</sub>, and CO<sub>2</sub> as a cushion gas candidate, with H<sub>2</sub> mole fractions in the gas-rich phase <i>x</i><sub>H<sub>2</sub></sub> = 0.7 and 0.3. The MD results are reasonably consistent with those obtained by density gradient theory based on the CPA equation of state. Our computed interfacial tensions (IFTs) are also reasonably consistent with experiments. Our previous studies showed that the IFTs of the H<sub>2</sub> + water system were not strongly influenced by pressure, and they decreased with increasing temperature. The IFTs of the H<sub>2</sub> + cushion gas + water system decreased with decreasing <i>x</i><sub>H<sub>2</sub></sub>. A key observation is that the effect of gas type on the IFTs of the H<sub>2</sub> + cushion gas + water system followed the order: CO<sub>2</sub> > CH<sub>4</sub> ≈ N<sub>2</sub>. This can be attributed to the relatively high surface excess of CO<sub>2</sub>. We also performed MD simulations of the H<sub>2</sub> + cushion gas + water + silica (hydrophilic) and H<sub>2</sub> + cushion gas + water + silica (hydrophobic) systems. Our previous studies showed that the water contact angles (CAs) of the H<sub>2</sub> + water + silica systems were not strongly influenced by the pressure or temperature. The water CAs of the H<sub>2</sub> + cushion gas + water + silica systems increased with decreasing <i>x</i><sub>H<sub>2</sub></sub>. Importantly, the effect of gas type on the water CAs of the H<sub>2</sub> + cushion gas + water + silica systems followed the order: CO<sub>2</sub> > CH<sub>4</sub> > N<sub>2</sub>. The capillary pressure of the H<sub>2</sub> + cushion gas + water + silica (hydrophilic) system decreased with decreasing <i>x</i><sub>H<sub>2</sub></sub>, suggesting that the studied gases might enhance the withdrawal process of H<sub>2</sub> in UHS.

Publication Details

Journal
Figshare
Published
2025-07-23
DOI
https://doi.org/10.1021/acs.langmuir.5c01958.s001
Primary Topic
Mycorrhizal Fungi and Plant Interactions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Molecular Insightsinto the Effects of Cushion Gason Underground Hydrogen Storage

Figshare
Mycorrhizal Fungi and Plant Interactions
article

Molecular Insightsinto the Effects of Cushion Gason Underground Hydrogen Storage

article en

Abstract

In underground hydrogen storage (UHS), a cushion gas is commonly used to provide pressure support to assist the withdrawal of hydrogen. Molecular dynamics (MD) simulations of the H<sub>2</sub> + cushion gas + water ternary system were conducted at 323–448 K and 20–150 MPa. We considered N<sub>2</sub>, CH<sub>4</sub>, and CO<sub>2</sub> as a cushion gas candidate, with H<sub>2</sub> mole fractions in the gas-rich phase <i>x</i><sub>H<sub>2</sub></sub> = 0.7 and 0.3. The MD results are reasonably consistent with those obtained by density gradient theory based on the CPA equation of state. Our computed interfacial tensions (IFTs) are also reasonably consistent with experiments. Our previous studies showed that the IFTs of the H<sub>2</sub> + water system were not strongly influenced by pressure, and they decreased with increasing temperature. The IFTs of the H<sub>2</sub> + cushion gas + water system decreased with decreasing <i>x</i><sub>H<sub>2</sub></sub>. A key observation is that the effect of gas type on the IFTs of the H<sub>2</sub> + cushion gas + water system followed the order: CO<sub>2</sub> > CH<sub>4</sub> ≈ N<sub>2</sub>. This can be attributed to the relatively high surface excess of CO<sub>2</sub>. We also performed MD simulations of the H<sub>2</sub> + cushion gas + water + silica (hydrophilic) and H<sub>2</sub> + cushion gas + water + silica (hydrophobic) systems. Our previous studies showed that the water contact angles (CAs) of the H<sub>2</sub> + water + silica systems were not strongly influenced by the pressure or temperature. The water CAs of the H<sub>2</sub> + cushion gas + water + silica systems increased with decreasing <i>x</i><sub>H<sub>2</sub></sub>. Importantly, the effect of gas type on the water CAs of the H<sub>2</sub> + cushion gas + water + silica systems followed the order: CO<sub>2</sub> > CH<sub>4</sub> > N<sub>2</sub>. The capillary pressure of the H<sub>2</sub> + cushion gas + water + silica (hydrophilic) system decreased with decreasing <i>x</i><sub>H<sub>2</sub></sub>, suggesting that the studied gases might enhance the withdrawal process of H<sub>2</sub> in UHS.

Figshare
Clean water and sanitation
Openalex Percentile: Top 53%
Mycorrhizal Fungi and Plant Interactions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Molecular Insightsinto the Effects of Cushion Gason Underground Hydrogen Storage · Figshare (2025) | TGRS Research Map | TGRS