Application of three-dimensional fluid-attenuated inversion recovery sequence using artificial intelligence-assisted compressed sensing technique in intravenous gadolinium contrast-enhanced magnetic resonance imaging of inner ear

ObjectiveTo investigate the value of artificial intelligence-assisted compressed sensing (ACS) technology for intravenous gadolinium contrast-enhanced magnetic resonance imaging of the inner ear using three-dimensional fluid-attenuated inversion recovery (3D-FLAIR) sequence. MethodsThe patients received gadolinium contrast-enhanced magnetic resonance imaging using ACS and united compressed sensing (uCS) 3D-FLAIR at Zhongshan Hospital, Fudan University from January to November 2024 were prospectively enrolled. The repetition time was 16 000 ms, and acquisition time was 6 min 40 s and 10 min 24 s in ACS 3D-FLAIR and uCS 3D-FLAIR, respectively. The images on the two sequences were evaluated independently by two radiologists. The image quality of the two sequences was subjectively evaluated and compared. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were compared between the two sequences. The grading consistencies using two sequences and between the two doctors were analyzed. ResultsThere was no statistically difference in subjective score of image quality between the two sequences. SNR and CNR of the ACS 3D-FLAIR sequence were significantly higher than those of the uCS 3D-FLAIR sequence (P<0.001). The kappa values of grades of cochlear and vestibular endolymphatic hydrops were 0.942 and 0.888 using two sequences (P<0.001). The kappa values of grades of cochlear and vestibular endolymphatic hydrops using the ACS 3D-FLAIR sequence between the two doctors were 0.784 and 0.831, respectively (P<0.001); the kappa values of grades of cochlear and vestibular endolymphatic hydrops using uCS 3D-FLAIR sequence between the two doctors were 0.725 and 0.756, respectively (P<0.001). ConclusionsACS 3D-FLAIR could provide higher SNR and CNR than uCS 3D-FLAIR, and is more suitable for intravenous gadolinium contrast-enhanced magnetic resonance imaging of the inner ear; the endolymphatic hydrops grades using ACS 3D-FLAIR is similar to use uCS 3D-FLAIR.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-04-01
DOI
https://doi.org/10.12025/j.issn.1008-6358.2025.20250063
Primary Topic
Mycorrhizal Fungi and Plant Interactions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of three-dimensional fluid-attenuated inversion recovery sequence using artificial intelligence-assisted compressed sensing technique in intravenous gadolinium contrast-enhanced magnetic resonance imaging of inner ear

SHILAP Revista de lepidopterología
Mycorrhizal Fungi and Plant Interactions
article

Application of three-dimensional fluid-attenuated inversion recovery sequence using artificial intelligence-assisted compressed sensing technique in intravenous gadolinium contrast-enhanced magnetic resonance imaging of inner ear

article en

Abstract

ObjectiveTo investigate the value of artificial intelligence-assisted compressed sensing (ACS) technology for intravenous gadolinium contrast-enhanced magnetic resonance imaging of the inner ear using three-dimensional fluid-attenuated inversion recovery (3D-FLAIR) sequence. MethodsThe patients received gadolinium contrast-enhanced magnetic resonance imaging using ACS and united compressed sensing (uCS) 3D-FLAIR at Zhongshan Hospital, Fudan University from January to November 2024 were prospectively enrolled. The repetition time was 16 000 ms, and acquisition time was 6 min 40 s and 10 min 24 s in ACS 3D-FLAIR and uCS 3D-FLAIR, respectively. The images on the two sequences were evaluated independently by two radiologists. The image quality of the two sequences was subjectively evaluated and compared. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were compared between the two sequences. The grading consistencies using two sequences and between the two doctors were analyzed. ResultsThere was no statistically difference in subjective score of image quality between the two sequences. SNR and CNR of the ACS 3D-FLAIR sequence were significantly higher than those of the uCS 3D-FLAIR sequence (P<0.001). The kappa values of grades of cochlear and vestibular endolymphatic hydrops were 0.942 and 0.888 using two sequences (P<0.001). The kappa values of grades of cochlear and vestibular endolymphatic hydrops using the ACS 3D-FLAIR sequence between the two doctors were 0.784 and 0.831, respectively (P<0.001); the kappa values of grades of cochlear and vestibular endolymphatic hydrops using uCS 3D-FLAIR sequence between the two doctors were 0.725 and 0.756, respectively (P<0.001). ConclusionsACS 3D-FLAIR could provide higher SNR and CNR than uCS 3D-FLAIR, and is more suitable for intravenous gadolinium contrast-enhanced magnetic resonance imaging of the inner ear; the endolymphatic hydrops grades using ACS 3D-FLAIR is similar to use uCS 3D-FLAIR.

SHILAP Revista de lepidopterología
Sun Yat-sen University (CN), Fudan University (CN), People’s Hospital of Rizhao (CN), Zhongshan Hospital (CN), The First Affiliated Hospital, Sun Yat-sen University (CN)
Openalex Percentile: Top 53%
Mycorrhizal Fungi and Plant Interactions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.