A SURVEY OF DIAGNOSTIC X-RAY ROOM DESIGN AND SHIELDING INTEGRITY OF LEAD APRONS IN A STATE IN NORTH EASTERN NIGERIA

Background: X-ray facility design and shielding integrity is meant to optimize radiation safety of patients, staff and the general public. Objectives: To determine the conformity to x-ray room design standards and the functional efficacy of lead aprons in the surveyed facilities. Materials and Method: The survey was conducted in six radio diagnostic centers in Gombe State Nigeria, labeled A to F for anonymity. The building layout of the radiology departments was sketched to show the dimensions (L x B x H) and adjoining structures. Data sheets were also used to record information about radio-diagnostic facility. Lead aprons were inspected for defects by physical observation and by x-ray exposure. Results: The x-ray room dimension of the six radio diagnostic centers with A(24m2 ), B (14.8 m2 ), C (30 m2 ), D (36 m2 ), E (21.2 m2 ) and F (25 m2 ). All the walls of radio-diagnostic room of facility A, B, C and D were lined with 2 mm lead equivalent, whereas E and F were not. About 7 (38.8%) of lead aprons inspected were defective, while 11 (61.1%) were not defective. Conclusion: There are compromises noted in the design of facility B and majority of the lead aprons inspected showed good functional efficacy.

Institutions

Publication Details

Journal
JRRS
Published
2025-05-17
DOI
https://doi.org/10.82547/jrrs.vol34no1.40
Primary Topic
Mycorrhizal Fungi and Plant Interactions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A SURVEY OF DIAGNOSTIC X-RAY ROOM DESIGN AND SHIELDING INTEGRITY OF LEAD APRONS IN A STATE IN NORTH EASTERN NIGERIA

JRRS
Mycorrhizal Fungi and Plant Interactions
article

A SURVEY OF DIAGNOSTIC X-RAY ROOM DESIGN AND SHIELDING INTEGRITY OF LEAD APRONS IN A STATE IN NORTH EASTERN NIGERIA

article en

Abstract

Background: X-ray facility design and shielding integrity is meant to optimize radiation safety of patients, staff and the general public. Objectives: To determine the conformity to x-ray room design standards and the functional efficacy of lead aprons in the surveyed facilities. Materials and Method: The survey was conducted in six radio diagnostic centers in Gombe State Nigeria, labeled A to F for anonymity. The building layout of the radiology departments was sketched to show the dimensions (L x B x H) and adjoining structures. Data sheets were also used to record information about radio-diagnostic facility. Lead aprons were inspected for defects by physical observation and by x-ray exposure. Results: The x-ray room dimension of the six radio diagnostic centers with A(24m2 ), B (14.8 m2 ), C (30 m2 ), D (36 m2 ), E (21.2 m2 ) and F (25 m2 ). All the walls of radio-diagnostic room of facility A, B, C and D were lined with 2 mm lead equivalent, whereas E and F were not. About 7 (38.8%) of lead aprons inspected were defective, while 11 (61.1%) were not defective. Conclusion: There are compromises noted in the design of facility B and majority of the lead aprons inspected showed good functional efficacy.

JRRS
Nnamdi Azikiwe University (NG), Usmanu Danfodiyo University (NG), University of Maiduguri (NG), Gombe State University (NG)
Sustainable cities and communities
Openalex Percentile: Top 53%
Mycorrhizal Fungi and Plant Interactions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.