Ionization Characteristics\nof Glycan Homologues in\nVarious Modes of Electrospray

Fluorescence labeled glycan homologous mixtures were\nquantified\nusing fluorescence and then used to evaluate ionization performances\nin electrospray ionization at micro, nano, and femto flow modes. nanoESI\nproduced higher (2+ and 3+) charged ions adducted with sodium and\ncalcium. In comparison, femtoESI was found to favor the generation\nof [M + H]<sup>+</sup> ions against metal adducts, even with nonvolatile\nsalts up to 1 mM for NaCl and 100 μM for CaCl<sub>2</sub>. For\nlabeled glucose homopolymer (GHP) glycans, nanoESI and femtoESI had\n0.81 and 3 nM detection limits, respectively. With LC separation and\na much higher flow rate, conventional microflow ESI detected all glycans\nwith 10-fold lower concentrations. Overall, nanoESI had the optimum\nuniformity in the relative ionization efficiency (RIE). When summing\nup intensities of analyte ions formed with all charge carriers, the\nRIE of the midsized glycans (10 to 16 glucose units) appear to be\nuniform (RIE 95%–105%). For the smaller (1–5 glucose\nunits) glycan components, femtoESI provided better uniformity than\nnanoESI and conventional ESI. For the labeled IgG N-glycans, the impact\nof chemical structure on the ionization efficiency was revealed by\nthe strong correlation between their RIE trends in different ionization\nmodes.

Publication Details

Journal
Figshare
Published
2024-12-23
DOI
https://doi.org/10.1021/jasms.4c00425.s001
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ionization Characteristics\nof Glycan Homologues in\nVarious Modes of Electrospray

Figshare
Mass Spectrometry Techniques and Applications
article

Ionization Characteristics\nof Glycan Homologues in\nVarious Modes of Electrospray

article en

Abstract

Fluorescence labeled glycan homologous mixtures were\nquantified\nusing fluorescence and then used to evaluate ionization performances\nin electrospray ionization at micro, nano, and femto flow modes. nanoESI\nproduced higher (2+ and 3+) charged ions adducted with sodium and\ncalcium. In comparison, femtoESI was found to favor the generation\nof [M + H]<sup>+</sup> ions against metal adducts, even with nonvolatile\nsalts up to 1 mM for NaCl and 100 μM for CaCl<sub>2</sub>. For\nlabeled glucose homopolymer (GHP) glycans, nanoESI and femtoESI had\n0.81 and 3 nM detection limits, respectively. With LC separation and\na much higher flow rate, conventional microflow ESI detected all glycans\nwith 10-fold lower concentrations. Overall, nanoESI had the optimum\nuniformity in the relative ionization efficiency (RIE). When summing\nup intensities of analyte ions formed with all charge carriers, the\nRIE of the midsized glycans (10 to 16 glucose units) appear to be\nuniform (RIE 95%–105%). For the smaller (1–5 glucose\nunits) glycan components, femtoESI provided better uniformity than\nnanoESI and conventional ESI. For the labeled IgG N-glycans, the impact\nof chemical structure on the ionization efficiency was revealed by\nthe strong correlation between their RIE trends in different ionization\nmodes.

Figshare
Openalex Percentile: Top 68%
Mass Spectrometry Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.