Numerical study of battery thermal management system with added Iwp structure cooling channel design

The liquid cooling battery thermal management system (BTMS) is crucial for ensuring battery thermal safety. To address the limitations of inadequate cooling performance in conventional uniform channel, a liquid cooling system based on triply periodic minimal surfaces is proposed, with the Iwp structure filled in the coolant flow channels to enhance cooling performance. The effects of different channel designs, solid fractions, filled lengths, and coolant flow directions on the thermal characteristics of the BTMS are investigated. The results indicate that channels filled with the Iwp structure effectively enhance the heat dissipation performance of the battery pack. Among them, the Iwp-sheet channel achieves the best cooling effect, with the Tmax and ΔT of the battery pack reduced by 10.14 % and 10.63 %, compared to the conventional uniform channel. Considering both heat transfer performance and power consumption, it is more appropriate to fill the coolant flow channels with a solid fraction of less than 40 %. The temperature uniformity of the battery pack is prominent when the filled length is 100 mm. The channel with a bidirectional flow design exhibits excellent temperature consistency. Compared to the unidirectional flow channel, the Tmax and ΔT of the battery pack are reduced by 0.74 % and 13.11 %.

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2025-07-18
DOI
https://doi.org/10.1016/j.csite.2025.106725
Citations
2
Primary Topic
Mycorrhizal Fungi and Plant Interactions
Type
article
Field-Weighted Citation Impact
3.50
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical study of battery thermal management system with added Iwp structure cooling channel design

2 citations
Case Studies in Thermal Engineering
Mycorrhizal Fungi and Plant Interactions
3.50
article

Numerical study of battery thermal management system with added Iwp structure cooling channel design

article en
2 citations

Abstract

The liquid cooling battery thermal management system (BTMS) is crucial for ensuring battery thermal safety. To address the limitations of inadequate cooling performance in conventional uniform channel, a liquid cooling system based on triply periodic minimal surfaces is proposed, with the Iwp structure filled in the coolant flow channels to enhance cooling performance. The effects of different channel designs, solid fractions, filled lengths, and coolant flow directions on the thermal characteristics of the BTMS are investigated. The results indicate that channels filled with the Iwp structure effectively enhance the heat dissipation performance of the battery pack. Among them, the Iwp-sheet channel achieves the best cooling effect, with the Tmax and ΔT of the battery pack reduced by 10.14 % and 10.63 %, compared to the conventional uniform channel. Considering both heat transfer performance and power consumption, it is more appropriate to fill the coolant flow channels with a solid fraction of less than 40 %. The temperature uniformity of the battery pack is prominent when the filled length is 100 mm. The channel with a bidirectional flow design exhibits excellent temperature consistency. Compared to the unidirectional flow channel, the Tmax and ΔT of the battery pack are reduced by 0.74 % and 13.11 %.

Case Studies in Thermal EngineeringVol. 73
Affordable and clean energy
Openalex Percentile: Top 7%
Mycorrhizal Fungi and Plant Interactions
3.50
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.