Enabling Hours-Long Drift Correction with Nanometer Resolutionin Optical Microscopy through Reflection Interferometry of FiducialBeads

Optical microscopy excels at revealing the dynamics of biological systems in real time. However, focal drift limits most microscopy approaches to only several minutes in the absence of drift-mitigation strategies. Here we introduce <u>f</u>ocus <u>re</u>adjustment for <u>e</u>nhanced <u>v</u>ertical <u>r</u>esolution (FREVR), a method which uses micrometer-sized fiducial beads alongside the specimen. By tracking the interference fringes generated by these beads, FREVR can detect changes in focus position with nanometer precision. We showcase this approach on a microscope equipped with a high-speed CMOS camera used for bead tracking and a highly sensitive EMCCD camera tasked to quantify fluorescence with spectral resolution. Using this approach, we measured samples in focus for several hours on several single-molecule systems, as well as on mammalian cells having their actin filaments or membrane proteins fluorescently labeled. FREVR has the potential to dramatically increase the temporal and spatial resolution and the long-term stability of microscopy techniques.

Publication Details

Journal
Figshare
Published
2025-02-04
DOI
https://doi.org/10.1021/acs.nanolett.4c05234.s001
Primary Topic
Mycorrhizal Fungi and Plant Interactions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enabling Hours-Long Drift Correction with Nanometer Resolutionin Optical Microscopy through Reflection Interferometry of FiducialBeads

Figshare
Mycorrhizal Fungi and Plant Interactions
article

Enabling Hours-Long Drift Correction with Nanometer Resolutionin Optical Microscopy through Reflection Interferometry of FiducialBeads

article en

Abstract

Optical microscopy excels at revealing the dynamics of biological systems in real time. However, focal drift limits most microscopy approaches to only several minutes in the absence of drift-mitigation strategies. Here we introduce <u>f</u>ocus <u>re</u>adjustment for <u>e</u>nhanced <u>v</u>ertical <u>r</u>esolution (FREVR), a method which uses micrometer-sized fiducial beads alongside the specimen. By tracking the interference fringes generated by these beads, FREVR can detect changes in focus position with nanometer precision. We showcase this approach on a microscope equipped with a high-speed CMOS camera used for bead tracking and a highly sensitive EMCCD camera tasked to quantify fluorescence with spectral resolution. Using this approach, we measured samples in focus for several hours on several single-molecule systems, as well as on mammalian cells having their actin filaments or membrane proteins fluorescently labeled. FREVR has the potential to dramatically increase the temporal and spatial resolution and the long-term stability of microscopy techniques.

Figshare
Openalex Percentile: Top 55%
Mycorrhizal Fungi and Plant Interactions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Enabling Hours-Long Drift Correction with Nanometer Resolutionin Optical Microscopy through Reflection Interferometry of FiducialBeads · Figshare (2025) | TGRS Research Map | TGRS