Coordinated BES and UPFC control strategy for the frequency control of renewable integrated multi area power system

The load frequency control (LFC) is an important service in establishing the dynamic stability of the interconnected power system (IPS). Thus, this paper suggests the tilt-integral-derivative-filter (TIDF) using the water cycle algorithm (WCA) as the LFC regulator for the diverse sourced IPS, and the analysis is performed for 10% step load disturbance (SLD) on area 1. However, the efficaciousness of the TIDF controller performance is revealed with the performances of other controllers by performing the comparative analysis. Later, in order to attain the improvement in the system performance, a coordinated control approach of battery energy storage (BES) and a unified power flow controller (UPFC) is incorporated. The simulation analysis revealed the improvement in system performance to a considerable extent with the employment of the coordinated control strategy. The robustness of the proposed control strategy is finally validated by conducting the robustness test in terms of different loadings.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2024-11-14
DOI
https://doi.org/10.1051/e3sconf/202459105010/pdf
Primary Topic
Mycorrhizal Fungi and Plant Interactions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Coordinated BES and UPFC control strategy for the frequency control of renewable integrated multi area power system

Springer Link (Chiba Institute of Technology)
Mycorrhizal Fungi and Plant Interactions
article

Coordinated BES and UPFC control strategy for the frequency control of renewable integrated multi area power system

article en

Abstract

The load frequency control (LFC) is an important service in establishing the dynamic stability of the interconnected power system (IPS). Thus, this paper suggests the tilt-integral-derivative-filter (TIDF) using the water cycle algorithm (WCA) as the LFC regulator for the diverse sourced IPS, and the analysis is performed for 10% step load disturbance (SLD) on area 1. However, the efficaciousness of the TIDF controller performance is revealed with the performances of other controllers by performing the comparative analysis. Later, in order to attain the improvement in the system performance, a coordinated control approach of battery energy storage (BES) and a unified power flow controller (UPFC) is incorporated. The simulation analysis revealed the improvement in system performance to a considerable extent with the employment of the coordinated control strategy. The robustness of the proposed control strategy is finally validated by conducting the robustness test in terms of different loadings.

Springer Link (Chiba Institute of Technology)
Affordable and clean energy
Openalex Percentile: Top 62%
Mycorrhizal Fungi and Plant Interactions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Coordinated BES and UPFC control strategy for the frequency control of renewable integrated multi area power system · Springer Link (Chiba Institute of Technology) (2024) | TGRS Research Map | TGRS