Fusion andSolvent Evaporation Ionization Mass Spectrometryfor Rapid Detection of Microplastics (MPs)

Microplastic (MP) pollution has gradually become a significant environmental concern, as MPs are widely present in soil, beaches, oceans, and even the atmosphere. Rapid detection and identification of MPs are crucial for monitoring and assessing environmental pollution. In this study, a fusion and solvent evaporation ionization (FSEI) device, comprising a heated plate and nebulizer, was developed for the direct detection and identification of six types of MPs. In the mass spectra, these MPs presented characteristic mass intervals corresponding to the monomer, realizing a more intuitive identification. After optimization, FSEI-MS demonstrated high sensitivity, good linearity (<i>R</i><sup>2</sup> > 0.992), and accuracy (72.7–132.7%). Moreover, FSEI-MS realized discrimination of mixed MPs in terms of both time and spectra dimensions and was successfully applied to the detection of MPs in soil with good recoveries (82.6–117.5%, RSD < 13.2%). Furthermore, FSEI-MS overcame the environmental matrix interference and achieved the direct analysis of MPs in soil by utilizing a commercial spray bottle as the nebulizer. Overall, this research established a comprehensive methodology that integrates time-resolved and MS-based dimensions, offering a concise and efficient solution for MP analysis.

Publication Details

Journal
Figshare
Published
2025-02-19
DOI
https://doi.org/10.1021/acs.analchem.5c00137.s001
Primary Topic
Mycorrhizal Fungi and Plant Interactions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fusion andSolvent Evaporation Ionization Mass Spectrometryfor Rapid Detection of Microplastics (MPs)

Figshare
Mycorrhizal Fungi and Plant Interactions
article

Fusion andSolvent Evaporation Ionization Mass Spectrometryfor Rapid Detection of Microplastics (MPs)

article en

Abstract

Microplastic (MP) pollution has gradually become a significant environmental concern, as MPs are widely present in soil, beaches, oceans, and even the atmosphere. Rapid detection and identification of MPs are crucial for monitoring and assessing environmental pollution. In this study, a fusion and solvent evaporation ionization (FSEI) device, comprising a heated plate and nebulizer, was developed for the direct detection and identification of six types of MPs. In the mass spectra, these MPs presented characteristic mass intervals corresponding to the monomer, realizing a more intuitive identification. After optimization, FSEI-MS demonstrated high sensitivity, good linearity (<i>R</i><sup>2</sup> > 0.992), and accuracy (72.7–132.7%). Moreover, FSEI-MS realized discrimination of mixed MPs in terms of both time and spectra dimensions and was successfully applied to the detection of MPs in soil with good recoveries (82.6–117.5%, RSD < 13.2%). Furthermore, FSEI-MS overcame the environmental matrix interference and achieved the direct analysis of MPs in soil by utilizing a commercial spray bottle as the nebulizer. Overall, this research established a comprehensive methodology that integrates time-resolved and MS-based dimensions, offering a concise and efficient solution for MP analysis.

Figshare
Openalex Percentile: Top 55%
Mycorrhizal Fungi and Plant Interactions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Fusion andSolvent Evaporation Ionization Mass Spectrometryfor Rapid Detection of Microplastics (MPs) · Figshare (2025) | TGRS Research Map | TGRS