Microneedle-Based\nElectrochemical Array Patch for\nUltra-Antifouling and Ultra-Anti-Interference Monitoring of Subcutaneous\nOxygen

Oxygen saturation is a crucial indicator\nin the management\nof various\ndiseases and in preoperative diagnosis, and the detection of oxygen\ncontent is valuable in guiding clinical treatment. However, as the\nclassical and dominant oxygen detection strategies, current photoelectric\noximeters and electrochemical-based blood gas analyzers often suffer\nfrom significant interindividual variation and poor compliance, respectively.\nIn recent years, wearable microneedles (MNs) for analyzing biomarkers\nin interstitial fluid (ISF) have received great attention and recognition\nmainly for the reason that the content of the substances distributed\nin ISF has a better correlation with that in blood circulation compared\nwith other body fluids such as sweat and saliva. Herein, an MN-based\nelectrochemical array system was developed for continuous subcutaneous\noxygen sensing, in which gold-modified commercial acupuncture MNs\nwere used as the sensing units, and a tailored mini-workstation, a\nnonwoven fabric, and a water and air isolation membrane were integrated\nto fabricate a wearable array patch. Notably, a multifunctional swelling\nresin with good biocompatibility was adopted to decorate the MN surface\nas a protective layer and as an electrolyte gel. The swelling resin\nfeatured the ability to reduce epidermis secretions during the sensor\narray penetrating the skin and to decrease the interference of other\nbiomolecules in ISF for oxygen assay during measurement. This proposed\narray patch can perform the subcutaneous oxygen analysis in the physiological\nrange of 6–150 mmHg with high sensitivity (0.3817 μA/mmHg)\nand low theoretical limit of detection (5.06 mmHg). It also showed\ndecent stability and selectivity in the presence of several kinds\nof exogenous and endogenous substances. Finally, the patch accomplished\ncontinual monitoring of the subcutaneous oxygen content during long-term\nphysical exercise, showing great potential in providing warning about\nthe hypoxia status of the human body. It could be foreseen that this\nhigh-performance patch will play an active role in respiratory disease\nevaluation, surgical monitoring, and public health care.

Publication Details

Journal
Figshare
Published
2024-12-20
DOI
https://doi.org/10.1021/acs.analchem.4c04345.s001
Primary Topic
Mycorrhizal Fungi and Plant Interactions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microneedle-Based\nElectrochemical Array Patch for\nUltra-Antifouling and Ultra-Anti-Interference Monitoring of Subcutaneous\nOxygen

Figshare
Mycorrhizal Fungi and Plant Interactions
article

Microneedle-Based\nElectrochemical Array Patch for\nUltra-Antifouling and Ultra-Anti-Interference Monitoring of Subcutaneous\nOxygen

article en

Abstract

Oxygen saturation is a crucial indicator\nin the management\nof various\ndiseases and in preoperative diagnosis, and the detection of oxygen\ncontent is valuable in guiding clinical treatment. However, as the\nclassical and dominant oxygen detection strategies, current photoelectric\noximeters and electrochemical-based blood gas analyzers often suffer\nfrom significant interindividual variation and poor compliance, respectively.\nIn recent years, wearable microneedles (MNs) for analyzing biomarkers\nin interstitial fluid (ISF) have received great attention and recognition\nmainly for the reason that the content of the substances distributed\nin ISF has a better correlation with that in blood circulation compared\nwith other body fluids such as sweat and saliva. Herein, an MN-based\nelectrochemical array system was developed for continuous subcutaneous\noxygen sensing, in which gold-modified commercial acupuncture MNs\nwere used as the sensing units, and a tailored mini-workstation, a\nnonwoven fabric, and a water and air isolation membrane were integrated\nto fabricate a wearable array patch. Notably, a multifunctional swelling\nresin with good biocompatibility was adopted to decorate the MN surface\nas a protective layer and as an electrolyte gel. The swelling resin\nfeatured the ability to reduce epidermis secretions during the sensor\narray penetrating the skin and to decrease the interference of other\nbiomolecules in ISF for oxygen assay during measurement. This proposed\narray patch can perform the subcutaneous oxygen analysis in the physiological\nrange of 6–150 mmHg with high sensitivity (0.3817 μA/mmHg)\nand low theoretical limit of detection (5.06 mmHg). It also showed\ndecent stability and selectivity in the presence of several kinds\nof exogenous and endogenous substances. Finally, the patch accomplished\ncontinual monitoring of the subcutaneous oxygen content during long-term\nphysical exercise, showing great potential in providing warning about\nthe hypoxia status of the human body. It could be foreseen that this\nhigh-performance patch will play an active role in respiratory disease\nevaluation, surgical monitoring, and public health care.

Figshare
Openalex Percentile: Top 64%
Mycorrhizal Fungi and Plant Interactions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Microneedle-Based\nElectrochemical Array Patch for\nUltra-Antifouling and Ultra-Anti-Interference Monitoring of Subcutaneous\nOxygen · Figshare (2024) | TGRS Research Map | TGRS