Graphene–MultiwalledCarbon Nanotubes ModifiedGlassy Carbon Electrodes for Simultaneous Detection of Ascorbic Acid,Dopamine, and Uric Acid

This study compares the sensing performance of glassy carbon electrodes (GCE) modified with graphene (GR), multiwalled carbon nanotubes (MWCNTs), and graphene–multiwalled carbon nanotube (GR-MWCNT) composites for the simultaneous detection of ascorbic acid (AA), dopamine (DA), and uric acid (UA). Among these electrodes, GR-MWCNT/GCE exhibited the highest sensitivity and the lowest detection limit. Using differential pulse voltammetry (DPV), AA, DA, and UA can be simultaneously detected at low potentials of −0.032, 0.206, and 0.34 V vs Ag/AgCl, with sensitivities of 0.076, 1.38, and 0.181 μA μM<sup>–1</sup> and detection limits (LOD) of 6.71, 0.58, and 7.30 μM, respectively. The GR-MWCNT/GCE also demonstrated good stability, reproducibility, and excellent anti-interference capability. This newly fabricated sensor was confirmed to be applicable for the simultaneous detection of AA, DA, and UA in real serum and urine samples.

Publication Details

Journal
Figshare
Published
2025-02-20
DOI
https://doi.org/10.1021/acsomega.4c09646.s001
Primary Topic
Mycorrhizal Fungi and Plant Interactions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Graphene–MultiwalledCarbon Nanotubes ModifiedGlassy Carbon Electrodes for Simultaneous Detection of Ascorbic Acid,Dopamine, and Uric Acid

Figshare
Mycorrhizal Fungi and Plant Interactions
article

Graphene–MultiwalledCarbon Nanotubes ModifiedGlassy Carbon Electrodes for Simultaneous Detection of Ascorbic Acid,Dopamine, and Uric Acid

article en

Abstract

This study compares the sensing performance of glassy carbon electrodes (GCE) modified with graphene (GR), multiwalled carbon nanotubes (MWCNTs), and graphene–multiwalled carbon nanotube (GR-MWCNT) composites for the simultaneous detection of ascorbic acid (AA), dopamine (DA), and uric acid (UA). Among these electrodes, GR-MWCNT/GCE exhibited the highest sensitivity and the lowest detection limit. Using differential pulse voltammetry (DPV), AA, DA, and UA can be simultaneously detected at low potentials of −0.032, 0.206, and 0.34 V vs Ag/AgCl, with sensitivities of 0.076, 1.38, and 0.181 μA μM<sup>–1</sup> and detection limits (LOD) of 6.71, 0.58, and 7.30 μM, respectively. The GR-MWCNT/GCE also demonstrated good stability, reproducibility, and excellent anti-interference capability. This newly fabricated sensor was confirmed to be applicable for the simultaneous detection of AA, DA, and UA in real serum and urine samples.

Figshare
Openalex Percentile: Top 56%
Mycorrhizal Fungi and Plant Interactions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.