Coreactant-freeElectrochemiluminescence: ROS Generationvia Upconversion Nanoparticles-Sensitized Inverse Opal TiO<sub>2</sub> Photocatalysis under NIR Irradiation

Conventional electrochemiluminescence (ECL) systems typically rely on coreactants, such as hydrogen peroxide or dissolved oxygen, to generate reactive oxygen species (ROS), which are essential for effective light emission. However, these coreactants are inherently limited by self-decomposition and solubility constraints, which can hinder the detection accuracy and light emission efficiency of ECL systems. In this work, we propose an innovative method that eliminates the need for coreactants by utilizing inverse opal TiO<sub>2</sub> (IO-TiO<sub>2</sub>) coupled with upconversion nanoparticles (UCNPs) as a coreaction accelerator. By harnessing near-infrared (NIR) irradiation, UCNPs efficiently convert this light into ultraviolet (UV) light, stimulating IO-TiO<sub>2</sub> to generate ROS through water oxidation. The generated ROS subsequently reacts with luminol anion radicals, producing robust ECL emission while eliminating interference from luminescence caused by coreactants. Electron paramagnetic resonance (EPR) results confirm the generation of hydroxyl (•OH), singlet oxygen (<sup>1</sup>O<sub>2</sub>), and superoxide anion radicals (O<sub>2</sub><sup>•–</sup>) during the electrochemical water oxidation process, which ensured the feasibility of the experimental approach. To demonstrate the practical application of this method, human chorionic gonadotropin (HCG) was selected as a model analyte. This proposed ECL immunoassay exhibited high sensitivity and stability in detecting HCG, with a linear range of 4 pg/mL to 1 μg/mL and a low limit of detection (LoD) of 1.33 pg/mL (<i>S</i>/<i>N</i> = 3). This breakthrough offers a promising avenue for developing ECL systems that are more sensitive, efficient, and highly versatile, expanding the range of applications in bioanalysis and environmental monitoring.

Publication Details

Journal
Figshare
Published
2025-03-28
DOI
https://doi.org/10.1021/acs.analchem.5c01132.s001
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Coreactant-freeElectrochemiluminescence: ROS Generationvia Upconversion Nanoparticles-Sensitized Inverse Opal TiO2 Photocatalysis under NIR Irradiation

Figshare
Advanced biosensing and bioanalysis techniques
article

Coreactant-freeElectrochemiluminescence: ROS Generationvia Upconversion Nanoparticles-Sensitized Inverse Opal TiO2 Photocatalysis under NIR Irradiation

article en

Abstract

Conventional electrochemiluminescence (ECL) systems typically rely on coreactants, such as hydrogen peroxide or dissolved oxygen, to generate reactive oxygen species (ROS), which are essential for effective light emission. However, these coreactants are inherently limited by self-decomposition and solubility constraints, which can hinder the detection accuracy and light emission efficiency of ECL systems. In this work, we propose an innovative method that eliminates the need for coreactants by utilizing inverse opal TiO<sub>2</sub> (IO-TiO<sub>2</sub>) coupled with upconversion nanoparticles (UCNPs) as a coreaction accelerator. By harnessing near-infrared (NIR) irradiation, UCNPs efficiently convert this light into ultraviolet (UV) light, stimulating IO-TiO<sub>2</sub> to generate ROS through water oxidation. The generated ROS subsequently reacts with luminol anion radicals, producing robust ECL emission while eliminating interference from luminescence caused by coreactants. Electron paramagnetic resonance (EPR) results confirm the generation of hydroxyl (•OH), singlet oxygen (<sup>1</sup>O<sub>2</sub>), and superoxide anion radicals (O<sub>2</sub><sup>•–</sup>) during the electrochemical water oxidation process, which ensured the feasibility of the experimental approach. To demonstrate the practical application of this method, human chorionic gonadotropin (HCG) was selected as a model analyte. This proposed ECL immunoassay exhibited high sensitivity and stability in detecting HCG, with a linear range of 4 pg/mL to 1 μg/mL and a low limit of detection (LoD) of 1.33 pg/mL (<i>S</i>/<i>N</i> = 3). This breakthrough offers a promising avenue for developing ECL systems that are more sensitive, efficient, and highly versatile, expanding the range of applications in bioanalysis and environmental monitoring.

Figshare
Industry, innovation and infrastructure
Openalex Percentile: Top 54%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Coreactant-freeElectrochemiluminescence: ROS Generationvia Upconversion Nanoparticles-Sensitized Inverse Opal TiO<sub>2</sub> Photocatalysis under NIR Irradiation · Figshare (2025) | TGRS Research Map | TGRS