Moment Analysis\nof Solute Permeation Kinetics at the\nInterface of Spherical Molecular Aggregates by Using Partial Supplying\nHigh- Performance Liquid Chromatography

Partial supplying high-performance liquid chromatography\n(HPLC)\nwas proposed as an experimental method. Moment equations were systematically\ndeveloped for analyzing elution peak profiles measured by partial\nsupplying HPLC to study solute permeation kinetics at the interface\nof spherical molecular aggregates. The moment analysis method was\napplied to the determination of partition equilibrium and interfacial\nsolute permeation rate constants of three solutes to sodium dodecyl\nsulfate (SDS) micelles. Their values were comparable with those determined\nby conventional HPLC, i.e., continuous supplying HPLC. Partial supplying\nHPLC experiments were conducted under the conditions that the ODS\nstationary phase surface is dynamically coated by SDS monomers. It\nwas tried to analyze how the length of the partially supplied SDS\nsolution zone changes due to diffusion phenomena during chromatographic\nprocesses. It was concluded that the moment analysis method using\npartial supplying HPLC is effective for the kinetic study of the interfacial\nsolute permeation of spherical molecular aggregates.

Publication Details

Journal
Figshare
Published
2024-12-31
DOI
https://doi.org/10.1021/acs.iecr.4c03661.s001
Primary Topic
Mycorrhizal Fungi and Plant Interactions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Moment Analysis\nof Solute Permeation Kinetics at the\nInterface of Spherical Molecular Aggregates by Using Partial Supplying\nHigh- Performance Liquid Chromatography

Figshare
Mycorrhizal Fungi and Plant Interactions
article

Moment Analysis\nof Solute Permeation Kinetics at the\nInterface of Spherical Molecular Aggregates by Using Partial Supplying\nHigh- Performance Liquid Chromatography

article en

Abstract

Partial supplying high-performance liquid chromatography\n(HPLC)\nwas proposed as an experimental method. Moment equations were systematically\ndeveloped for analyzing elution peak profiles measured by partial\nsupplying HPLC to study solute permeation kinetics at the interface\nof spherical molecular aggregates. The moment analysis method was\napplied to the determination of partition equilibrium and interfacial\nsolute permeation rate constants of three solutes to sodium dodecyl\nsulfate (SDS) micelles. Their values were comparable with those determined\nby conventional HPLC, i.e., continuous supplying HPLC. Partial supplying\nHPLC experiments were conducted under the conditions that the ODS\nstationary phase surface is dynamically coated by SDS monomers. It\nwas tried to analyze how the length of the partially supplied SDS\nsolution zone changes due to diffusion phenomena during chromatographic\nprocesses. It was concluded that the moment analysis method using\npartial supplying HPLC is effective for the kinetic study of the interfacial\nsolute permeation of spherical molecular aggregates.

Figshare
Openalex Percentile: Top 65%
Mycorrhizal Fungi and Plant Interactions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Moment Analysis\nof Solute Permeation Kinetics at the\nInterface of Spherical Molecular Aggregates by Using Partial Supplying\nHigh- Performance Liquid Chromatography · Figshare (2024) | TGRS Research Map | TGRS