Comparative Comparison Of Residential Buildings In Yazd's Central Yard In Terms Of Thermal Behavior By Measuring The Total Thermal Load

Today, the effect of the thermal behavior of materials and spaces in the face of climatic conditions in creating thermal comfort for humans has been proven. Although the buildings usually use fossil fuels and cause heavy consequences such as climate change, favorable thermal behavior is observed in the native buildings of the cities of the central plateau of Iran, including the houses with a central courtyard in Yazd. Therefore, the main goal of this article is to compare the thermal behavior of buildings with a central courtyard in the dry climate of Yazd, to check to what extent central courtyards can provide suitable thermal behavior for these buildings. Modeling and simulation methods have been used in this research. Twenty buildings with a central courtyard were selected in Yazd region and then modeled in Design Builder software. In order to achieve optimal thermal comfort due to the different substructures of these buildings, the total thermal and cooling load should be divided by the square meter of the building. to obtain the values of the total thermal load of the building in terms of kilowatt hours per square meter to provide a basis for comparing these buildings with each other. In line with the purpose of the research, the lower the amount of heating and cooling required and, consequently, the total load of a building, the better its performance in terms of climate. The results of this research showed that the lowest values of the total heating and cooling load belong to single-yard houses. It is like Samsar 142 kwh/m2 and Tehrani ha House 162 kwh/m2 and Rasoulian House 181 kwh/m2. In this way, a comparative comparison can be made from the lowest to the highest amount of energy consumption in native houses in Yazd. According to this Yandi classification, a new typology of residential buildings in the central yard of Yazd can be obtained from the comparative comparison of the buildings in terms of thermal behavior based on the total thermal load. which is a proof of innovation in this research compared to similar researches in this field.

Institutions

Publication Details

Journal
Creative City Design
Published
2024-08-15
DOI
https://doi.org/10.71619/crcd-2024-8177
Primary Topic
Mycorrhizal Fungi and Plant Interactions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Comparison Of Residential Buildings In Yazd's Central Yard In Terms Of Thermal Behavior By Measuring The Total Thermal Load

Creative City Design
Mycorrhizal Fungi and Plant Interactions
article

Comparative Comparison Of Residential Buildings In Yazd's Central Yard In Terms Of Thermal Behavior By Measuring The Total Thermal Load

article en

Abstract

Today, the effect of the thermal behavior of materials and spaces in the face of climatic conditions in creating thermal comfort for humans has been proven. Although the buildings usually use fossil fuels and cause heavy consequences such as climate change, favorable thermal behavior is observed in the native buildings of the cities of the central plateau of Iran, including the houses with a central courtyard in Yazd. Therefore, the main goal of this article is to compare the thermal behavior of buildings with a central courtyard in the dry climate of Yazd, to check to what extent central courtyards can provide suitable thermal behavior for these buildings. Modeling and simulation methods have been used in this research. Twenty buildings with a central courtyard were selected in Yazd region and then modeled in Design Builder software. In order to achieve optimal thermal comfort due to the different substructures of these buildings, the total thermal and cooling load should be divided by the square meter of the building. to obtain the values of the total thermal load of the building in terms of kilowatt hours per square meter to provide a basis for comparing these buildings with each other. In line with the purpose of the research, the lower the amount of heating and cooling required and, consequently, the total load of a building, the better its performance in terms of climate. The results of this research showed that the lowest values of the total heating and cooling load belong to single-yard houses. It is like Samsar 142 kwh/m2 and Tehrani ha House 162 kwh/m2 and Rasoulian House 181 kwh/m2. In this way, a comparative comparison can be made from the lowest to the highest amount of energy consumption in native houses in Yazd. According to this Yandi classification, a new typology of residential buildings in the central yard of Yazd can be obtained from the comparative comparison of the buildings in terms of thermal behavior based on the total thermal load. which is a proof of innovation in this research compared to similar researches in this field.

Creative City Design
Islamic Azad University, Damghan Branch (IR), Iran University of Science and Technology (IR)
Affordable and clean energy
Openalex Percentile: Top 70%
Mycorrhizal Fungi and Plant Interactions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.