Comparing performance and complexity of TCHB and CHB multilevel inverters using NLC technique

This paper presents a modulation strategy applied to a 13-level three-phase transistor clamped H-bridge (TCHB) inverter, aimed at a renewable and electric vehicle drives application. A comparison is performed between the TCHB inverter and a traditional cascaded H-bridge (CHB) inverter, considering circuit complexity, switching losses, and total harmonic distortion (THD) attained from each multilevel inverter topologies. The TCHB inverter achieves a 13-level output with only 15 switches, whereas the conventional CHB inverter requires 24 switches. The modulation technique, employing a nearest level control, yields improved output quality for both the TCHB and CHB multilevel inverters. The results demonstrate that this strategy effectively minimizes the overall THD. Notably, previous modulation techniques mainly focused on carrier-based PWM or SVPWM, making this approach distinctive. The FFT analysis reveals a voltage THD of 5.49% for TCHB and 5.15% for CHB, indicating a marginal difference in THD content for each multilevel inverter. Despite the CHB inverter experiencing double the switching stress compared to TCHB, since less switches are required in the TCHB inverter, consequently, the system's total cost and complexity are reduced. The achieved results are verified through the use of simulations carried out in the MATLAB Simulink.<br>

Publication Details

Journal
Figshare
Published
2024-08-15
DOI
https://doi.org/10.6084/m9.figshare.26702098
Primary Topic
Mycorrhizal Fungi and Plant Interactions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparing performance and complexity of TCHB and CHB multilevel inverters using NLC technique

Figshare
Mycorrhizal Fungi and Plant Interactions
article

Comparing performance and complexity of TCHB and CHB multilevel inverters using NLC technique

article en

Abstract

This paper presents a modulation strategy applied to a 13-level three-phase transistor clamped H-bridge (TCHB) inverter, aimed at a renewable and electric vehicle drives application. A comparison is performed between the TCHB inverter and a traditional cascaded H-bridge (CHB) inverter, considering circuit complexity, switching losses, and total harmonic distortion (THD) attained from each multilevel inverter topologies. The TCHB inverter achieves a 13-level output with only 15 switches, whereas the conventional CHB inverter requires 24 switches. The modulation technique, employing a nearest level control, yields improved output quality for both the TCHB and CHB multilevel inverters. The results demonstrate that this strategy effectively minimizes the overall THD. Notably, previous modulation techniques mainly focused on carrier-based PWM or SVPWM, making this approach distinctive. The FFT analysis reveals a voltage THD of 5.49% for TCHB and 5.15% for CHB, indicating a marginal difference in THD content for each multilevel inverter. Despite the CHB inverter experiencing double the switching stress compared to TCHB, since less switches are required in the TCHB inverter, consequently, the system's total cost and complexity are reduced. The achieved results are verified through the use of simulations carried out in the MATLAB Simulink.<br>

Figshare
Affordable and clean energy
Openalex Percentile: Top 74%
Mycorrhizal Fungi and Plant Interactions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.