RESPONSE TIME AND RECOVERY TIME OF A SEMICONDUCTOR SENSOR FOR DETECTING METHANE AND NATURAL GAS

RESPONSE TIME AND RECOVERY TIME OF A SEMICONDUCTOR SENSOR FOR DETECTING METHANE AND NATURAL GAS Khodieva Nargiza Djurakulovna Assistant at the Samarkand State architectural and civil-engineering university Eshkobilova Mavjuda Ergashboyevna Associate Professor at the Samarkand State Medical University https://doi.org/10.5281/zenodo.15512498 Abstract: The response and recovery times of gas sensors provide insights into their dynamic behavior and are determined through experimental methods. The response time refers to the period needed for the sensor to reach 90% of its final signal value after exposure to a sudden change in gas concentration. This is often labeled as τ₀₉ or τ_response. Conversely, the recovery time, denoted as τ₀₁ or τ_recovery, is the time taken for the sensor to return to 10% of its initial baseline value after the gas is removed and clean air is introduced. Keywords: Nanocomposite metal oxides, Gas sensors, Methane detection, Natural gas sensing, Semiconductor sensors, SnO₂, ZnO, WO₃ Sol-gel synthesis.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-05-25
DOI
https://doi.org/10.5281/zenodo.15512498
Primary Topic
Statistical Mechanics and Entropy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

RESPONSE TIME AND RECOVERY TIME OF A SEMICONDUCTOR SENSOR FOR DETECTING METHANE AND NATURAL GAS

Zenodo (CERN European Organization for Nuclear Research)
Statistical Mechanics and Entropy
article

RESPONSE TIME AND RECOVERY TIME OF A SEMICONDUCTOR SENSOR FOR DETECTING METHANE AND NATURAL GAS

article en

Abstract

RESPONSE TIME AND RECOVERY TIME OF A SEMICONDUCTOR SENSOR FOR DETECTING METHANE AND NATURAL GAS Khodieva Nargiza Djurakulovna Assistant at the Samarkand State architectural and civil-engineering university Eshkobilova Mavjuda Ergashboyevna Associate Professor at the Samarkand State Medical University https://doi.org/10.5281/zenodo.15512498 Abstract: The response and recovery times of gas sensors provide insights into their dynamic behavior and are determined through experimental methods. The response time refers to the period needed for the sensor to reach 90% of its final signal value after exposure to a sudden change in gas concentration. This is often labeled as τ₀₉ or τ_response. Conversely, the recovery time, denoted as τ₀₁ or τ_recovery, is the time taken for the sensor to return to 10% of its initial baseline value after the gas is removed and clean air is introduced. Keywords: Nanocomposite metal oxides, Gas sensors, Methane detection, Natural gas sensing, Semiconductor sensors, SnO₂, ZnO, WO₃ Sol-gel synthesis.

Zenodo (CERN European Organization for Nuclear Research)
Samarkand State Architectural and Civil-Engineering Institute (UZ), Samarkand State Medical Institute (UZ)
Openalex Percentile: Top 58%
Statistical Mechanics and Entropy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

RESPONSE TIME AND RECOVERY TIME OF A SEMICONDUCTOR SENSOR FOR DETECTING METHANE AND NATURAL GAS · Zenodo (CERN European Organization for Nuclear Research) (2025) | TGRS Research Map | TGRS