Energize Transformer 400kVA at State Polytechnic of Samarinda with Simulation

Abstract : The purpose of this study is to analyze the performance and effectiveness of the Energize 400kVA Transformer model which acts as a step-up transformer in the electric power distribution system. The focus of this study is to evaluate the efficiency of the transformer in increasing the voltage from medium to higher levels and the impact of this conversion on power stability, energy losses, and thermal resistance.Testing was carried out by operating the transformer at various load levels and measuring performance parameters such as copper and iron losses, voltage regulation, and cooling capacity. The results showed that the Energize Transformer 400kVA can operate optimally as a step-up transformer with high efficiency in the load range of 70-90% of full capacity and good voltage stability when the load changes. The transformer cooling system also proved effective in maintaining the operating temperature within safe limits, thus contributing to a longer service life and shorter maintenance intervals. Based on these results, the Energize Transformer 400 kVA model is suitable for use as a step-up transformer in medium to large distribution networks, supporting optimal power quality and high operational efficiency.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-11-20
DOI
https://doi.org/10.5281/zenodo.14190315
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Energize Transformer 400kVA at State Polytechnic of Samarinda with Simulation

Zenodo (CERN European Organization for Nuclear Research)
Power Transformer Diagnostics and Insulation
article

Energize Transformer 400kVA at State Polytechnic of Samarinda with Simulation

article en

Abstract

Abstract : The purpose of this study is to analyze the performance and effectiveness of the Energize 400kVA Transformer model which acts as a step-up transformer in the electric power distribution system. The focus of this study is to evaluate the efficiency of the transformer in increasing the voltage from medium to higher levels and the impact of this conversion on power stability, energy losses, and thermal resistance.Testing was carried out by operating the transformer at various load levels and measuring performance parameters such as copper and iron losses, voltage regulation, and cooling capacity. The results showed that the Energize Transformer 400kVA can operate optimally as a step-up transformer with high efficiency in the load range of 70-90% of full capacity and good voltage stability when the load changes. The transformer cooling system also proved effective in maintaining the operating temperature within safe limits, thus contributing to a longer service life and shorter maintenance intervals. Based on these results, the Energize Transformer 400 kVA model is suitable for use as a step-up transformer in medium to large distribution networks, supporting optimal power quality and high operational efficiency.

Zenodo (CERN European Organization for Nuclear Research)
Universitas 17 Agustus 1945 Samarinda (ID)
Affordable and clean energy
Openalex Percentile: Top 67%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Energize Transformer 400kVA at State Polytechnic of Samarinda with Simulation · Zenodo (CERN European Organization for Nuclear Research) (2024) | TGRS Research Map | TGRS