Physio-chemical and bacteriological quality of well water from Kottayam district, Kerala

This study focused on determining of physio-chemical, Biological and Weighed water quality index of well water samples from twelve different stations in Kottayam district, Kerala. The water samples analyzed for physio-chemical parameters including pH, Electrical conductivity, TDS (Total Dissolved Solids), Total iron, Bacterial contamination and water quality index was calculated. All 120 samples were analyzed separately and were compared with the water quality standard prescribed by the APHA and IS 3025. It was found that the mean pH values showed slight variations ranging from 5.85±0.72- 7.19±2.09. The electrical conductivity showed variations ranging from 64.9±46.34- to 366.4±561.8. The well water samples were shown the TDS value under the permissible limit with a range of 42±39.8-248.2±393.03. A significant variation in total iron value was obtained from the Neendoor station and the range is 0.0033±0.0069-0.5525±1.703. Weighted water quality index was calculated based on physiochemical parameters and it is evident that the water from Neendoor station is unsuitable for drinking purposes. The bacterial concentrations of Pampady station showed 90% contamination and 65.8% of water samples were showed Indicator organism Escherichia coli.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-08-30
DOI
https://doi.org/10.5281/zenodo.14833476
Primary Topic
Stress Responses and Cortisol
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Physio-chemical and bacteriological quality of well water from Kottayam district, Kerala

Zenodo (CERN European Organization for Nuclear Research)
Stress Responses and Cortisol
article

Physio-chemical and bacteriological quality of well water from Kottayam district, Kerala

article en

Abstract

This study focused on determining of physio-chemical, Biological and Weighed water quality index of well water samples from twelve different stations in Kottayam district, Kerala. The water samples analyzed for physio-chemical parameters including pH, Electrical conductivity, TDS (Total Dissolved Solids), Total iron, Bacterial contamination and water quality index was calculated. All 120 samples were analyzed separately and were compared with the water quality standard prescribed by the APHA and IS 3025. It was found that the mean pH values showed slight variations ranging from 5.85±0.72- 7.19±2.09. The electrical conductivity showed variations ranging from 64.9±46.34- to 366.4±561.8. The well water samples were shown the TDS value under the permissible limit with a range of 42±39.8-248.2±393.03. A significant variation in total iron value was obtained from the Neendoor station and the range is 0.0033±0.0069-0.5525±1.703. Weighted water quality index was calculated based on physiochemical parameters and it is evident that the water from Neendoor station is unsuitable for drinking purposes. The bacterial concentrations of Pampady station showed 90% contamination and 65.8% of water samples were showed Indicator organism Escherichia coli.

Zenodo (CERN European Organization for Nuclear Research)
Government Medical College (IN)
Clean water and sanitation
Openalex Percentile: Top 59%
Stress Responses and Cortisol
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.