Development of Chromatographic Method for The Simultaneous Estimation of Solifenacin and Mirabegron in Combination Tablet Dosage form

A simple, accurate, and precise reverse-phase high-performance liquid chromatographic (RP-HPLC) method was developed and validated for the simultaneous estimation of Solifenacin Succinate and Mirabegron in a combined tablet dosage form. The method employed a C18 column with a mobile phase consisting of acetonitrile and phosphate buffer (pH adjusted to 3.5 with orthophosphoric acid) in a 60:40 v/v ratio. The flow rate was maintained at 1.0 mL/min and detection was carried out at 220 nm. The retention times for Solifenacin and Mirabegron were found to be approximately 3.8 and 6.2 minutes, respectively. The method was validated as per ICH guidelines and showed good linearity (r² > 0.999), precision (RSD < 2%), accuracy (recoveries within 98-102%), and robustness. This method can be successfully applied for routine quality control and stability studies of Solifenacin and Mirabegron in combined pharmaceutical formulations.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-08-09
DOI
https://doi.org/10.5281/zenodo.16785548
Primary Topic
Prenatal Screening and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of Chromatographic Method for The Simultaneous Estimation of Solifenacin and Mirabegron in Combination Tablet Dosage form

Zenodo (CERN European Organization for Nuclear Research)
Prenatal Screening and Diagnostics
article

Development of Chromatographic Method for The Simultaneous Estimation of Solifenacin and Mirabegron in Combination Tablet Dosage form

article en

Abstract

A simple, accurate, and precise reverse-phase high-performance liquid chromatographic (RP-HPLC) method was developed and validated for the simultaneous estimation of Solifenacin Succinate and Mirabegron in a combined tablet dosage form. The method employed a C18 column with a mobile phase consisting of acetonitrile and phosphate buffer (pH adjusted to 3.5 with orthophosphoric acid) in a 60:40 v/v ratio. The flow rate was maintained at 1.0 mL/min and detection was carried out at 220 nm. The retention times for Solifenacin and Mirabegron were found to be approximately 3.8 and 6.2 minutes, respectively. The method was validated as per ICH guidelines and showed good linearity (r² > 0.999), precision (RSD < 2%), accuracy (recoveries within 98-102%), and robustness. This method can be successfully applied for routine quality control and stability studies of Solifenacin and Mirabegron in combined pharmaceutical formulations.

Zenodo (CERN European Organization for Nuclear Research)
Industry, innovation and infrastructure
Openalex Percentile: Top 45%
Prenatal Screening and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.