QUANTIFICATION OF CAPECITABINE IN LIPID BASED NANOFORMULATION USING AN OPTIMISED AND VALIDATED REVERSE PHASE HPLC METHOD.

Abstract- Capecitabine, a prodrug of 5-fluorouracil, is widely used in cancer therapy but its accurate determination inlipid-based nano formulations presents analytical challenges. A C18 column and Methanol and Millipore water with0.1% OPA (80:20, v/ v) was used to optimize the reverse phase-HPLC-UV method. Capecitabine was identified at 230nm while keeping the flow rate at 1 mL/minute. The optimised method was validated, which proved to be in compliancewith ICH Q2 (R1) guidelines. The R2 value was found to be 0.998 indicating satisfactory linear plot within the givenrange. Lower Recovery experiments with respectable percentage recoveries confirmed to the method's accuracy. Thenew technique can, hence, be effectively utilised to measure capecitabine loaded lipid-based nano formulations.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-06-23
DOI
https://doi.org/10.5281/zenodo.15720952
Primary Topic
Network Packet Processing and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

QUANTIFICATION OF CAPECITABINE IN LIPID BASED NANOFORMULATION USING AN OPTIMISED AND VALIDATED REVERSE PHASE HPLC METHOD.

Zenodo (CERN European Organization for Nuclear Research)
Network Packet Processing and Optimization
article

QUANTIFICATION OF CAPECITABINE IN LIPID BASED NANOFORMULATION USING AN OPTIMISED AND VALIDATED REVERSE PHASE HPLC METHOD.

article en

Abstract

Abstract- Capecitabine, a prodrug of 5-fluorouracil, is widely used in cancer therapy but its accurate determination inlipid-based nano formulations presents analytical challenges. A C18 column and Methanol and Millipore water with0.1% OPA (80:20, v/ v) was used to optimize the reverse phase-HPLC-UV method. Capecitabine was identified at 230nm while keeping the flow rate at 1 mL/minute. The optimised method was validated, which proved to be in compliancewith ICH Q2 (R1) guidelines. The R2 value was found to be 0.998 indicating satisfactory linear plot within the givenrange. Lower Recovery experiments with respectable percentage recoveries confirmed to the method's accuracy. Thenew technique can, hence, be effectively utilised to measure capecitabine loaded lipid-based nano formulations.

Zenodo (CERN European Organization for Nuclear Research)
JSS Academy of Higher Education and Research (IN)
Openalex Percentile: Top 49%
Network Packet Processing and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

QUANTIFICATION OF CAPECITABINE IN LIPID BASED NANOFORMULATION USING AN OPTIMISED AND VALIDATED REVERSE PHASE HPLC METHOD. · Zenodo (CERN European Organization for Nuclear Research) (2025) | TGRS Research Map | TGRS